Uma unidade da AKRIBIS One
HiTemp140-FP-6

Lugares na árvore

  • GrandezaInstrumentos › Temperatura › Registradores de dados

Marca

MadgeTech

Filtros

Grau de proteção
IP68
Tipo de sensor
RTD (Pt100, Pt1000)
Características
Ultrabaixa temperatura, Alta temperatura, Submersível, Bateria substituível
Material
Aço inoxidável
Uso
Reutilizável
Alimentação
Bateria
Faixa de temperatura
-200 – 260 °C
Exatidão de temperatura
0.1 °C
Memória (leituras)
32356
Duração da bateria
24 meses

HiTemp140-FP (HiTemp140-FP-6)

The HiTemp140-FP is a high temperature data logger with a flexible RTD probe. Includes ISO17025 accredited calibration certificate.

Solicitar cotaçãoBaixar ficha técnica

HiTemp140-FP (HiTemp140-FP-6)

Key Features

  • ±0.1 °C Accuracy
  • Available in a Variety of Probe Lengths
  • Probe Measures Temperatures up to 260 °C

Description

The HiTemp140-FP is a high temperature data logger built for use in harsh environments. The body of the HiTemp140-FP can withstand temperatures ranging from -40 °C to +140 °C (-40 °F to +284 °F), but can extend to higher temperatures when used with MadgeTech’s thermal barrier options.

The HiTemp140-FP is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

General

Memory32,356 readings
Reading Rate1 reading every 0.25 seconds up to 1 reading every 24 hours
Baud Rate125,000
Battery Life2 years typical (1 minute reading rate); Fast reading intervals and extreme temperatures will shorten the battery life substantially; User Replaceable Battery
MaterialBody: 316 Stainless Steel, Radel; Probe: PFA Insulated Cable with Stainless Steel Tip
DimensionsBody: 2.95 in x 0.97 in x 0.97 in (75 mm x 24.6 mm x 24.6 mm); Probes: HiTemp140-FPST-6: 6 in x 0.13 in (152.5 mm x 3.2 mm); HiTemp140-FPST-12: 12 in x 0.13 in (304.8 mm x 3.2 mm); HiTemp140-FPST-36: 36 in x 0.13 in (914 mm x 3.2 mm); HiTemp140-FPST-72: 72 in x 0.13 in (1829 mm x 3.2 mm)
Key Ring End CapKey ring replaces standard bottom; Thru-hole: 0.150"
IP RatingIP68
SubmersibleYes
Operating Environment-40 °C to +140 °C (-40 °F to +284 °F) Body of Logger Cannot Exceed 140 °C; 0 %RH to 100 %RH, 0 PSIA to 100 PSIA; With Thermal Shield: -200 °C to +250 °C (-328 °F to +482 °F)
Required Interface PackageIFC400 or IFC406
ApprovalsCE
Weight0.1875 LBS

Temperature

Temperature SensorFlexible RTD Probe
Temperature Resolution0.01 °C (0.018 °F)
Temperature Calibrated Accuracy±0.1 °C from +20 °C to +140 °C; ±0.3 °C from -20 °C to +19.99 °C; ±0.4 °C from -40 °C to -20.01 °C
Probe Temperature Range-200 °C to +260 °C (-328 °F to +500 °F); (Body of Logger Cannot Exceed 140 °C)

Configurar o equipamento

Escolha modelo, sondas e acessórios. As combinações incompatíveis são bloqueadas na hora; as demais regras são verificadas ao adicionar o equipamento à cotação.

Documentos