A unit of AKRIBIS One
PRTemp140-NPT

Places in the tree

  • MeasurementInstruments › Pressure › Data loggers
  • MeasurementInstruments › Temperature › Data loggers

Brand

MadgeTech

Filters

Protection rating
IP68
Sensor type
RTD (Pt100, Pt1000), Semiconductor
Features
Submersible
Material
Stainless steel
Use
Reusable
Power supply
Battery
Pressure type
Gauge or absolute
Temperature range
-20 – 140 °C
Pressure range
0 – 5 bar
Temperature accuracy
0.1 °C
Memory (readings)
16128
Battery life
24 meses

PRTemp140 (PRTemp140-NPT)

The PRTemp140 is a submersible, pressure and high temperature data logger. Includes ISO17025 accredited calibration certificate.

Request a quoteDownload the datasheet

PRTemp140 (PRTemp140-NPT)

Key Features

  • Submersible
  • 2.5 Inches Tall
  • Available in Flush or NPT Pressure Port Top
PRTemp140 (PRTemp140-NPT)

Description

The PRTemp140 is a submersible, pressure and high temperature data logger. Available with a flush top or 1/8-27 NPT top model, this device stands less than 2.5 in. high, allowing it to fit discretely inside small spaces.

This data logger is able to measure and record temperatures from -20 °C to 140 °C (-4 °F to +284 °F) and absolute pressure from 0 bar to 5 bar, accommodating a wide range of applications even in the harshest conditions. The PRTemp140 can store a maximum of 16,128 time and date stamped readings and can even be programmed to start up to 18 months in advance.

The PRTemp140 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

PRTemp140 (PRTemp140-NPT)

General

Memory16,128 readings (all channels enabled)
Reading Rate1 second to once every 24 hours, selectable in software
Baud Rate125,000
Battery Life2 years typical (1 minute reading rate); Note: Fast reading intervals and extreme temperatures will shorten the battery life substantially
Material316 Stainless Steel, Radel
DimensionsFlush Top: 1.98 in x 0.97 in x 0.97 in (50.2 mm x 24.6 mm x 24.6 mm); NPT Top: 2.30 in x 0.97 in x 0.97 in (58.2 mm x 24.6 mm x 24.6 mm)
IP RatingIP68
SubmersibleYes
Operating Environment-20 °C to +140 °C (-4 °F to +284 °F), 0 %RH to 100 %RH
ApprovalsCE

Temperature

Temperature SensorResistance Temperature Detector (RTD)
Temperature Range-20 °C to +140 °C (-4 °F to +284 °F)
Temperature Resolution0.01 °C (0.018 °F)
Temperature Calibrated Accuracy±0.1 °C from +20 °C to +140 °C (68 °F to 284 °F); ±0.3 °C from -20 °C to +19.99 °C (-4 °F to +68 °F)

Pressure

Pressure SensorSemiconductor Strain Gauge
Pressure Range0 to 5 Bar (0 to 72.5 PSIA)
Pressure Resolution0.0001 bar
Pressure Calibrated Accuracy±0.03 bar (±0.435 PSI) from +20 °C to +140 °C (+68 °F to +284 °F); ±0.1 bar (±1.45 PSI) from -20 °C to +19.99 °C (-4 °F to +68 °F)

Configure the instrument

Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.

Documents

  • MagMount-1

    MagMount-1

    Magnetic Holder for use with the PR140, PRTemp140, HiTemp140, Temp1000, and RHTemp1000 Series Data Loggers.

  • IFC400

    IFC400

    Interface Cable Package for the HiTemp140 and PR140 Data Loggers.

  • IFC406

    IFC406

    IFC406 Multiplexer Data Logger Interface.

  • DLS100

    DLS100

    Versatile stand for use with the HiTemp140, PRTemp140, PR140, Temp1000 and RHTemp1000 series of data loggers.

  • Luer-Fitting - F

    LUER-FITTING-F

    316 stainless steel, 1/8 in NPT to Female luer lock adapter

  • Key Ring End Cap

    Key Ring End Cap

    Optional “Key Ring” end cap.