CAB100 Industrial Cabinet for continuous monitoring systems
for cleanrooms and industrial settings
Nota de aplicación
Sodium hydroxide or caustic soda is an inorganic compound with the formula NaOH. It is a white, translucent and hygroscopic solid, which forms a strong alkaline solution with water.
Sodium hydroxide is used as a caustic base and alkali in a wide range of industries.

Chemical curve: Sodium hydroxide R.I. per Conc % b.w. at Ref. Temp. of 20˚C
Sodium hydroxide is manufactured by electrolysis of sodium chloride solutions. Brine (NaCl in water) electrolysis produces chloride at the anode and hydrogen, along with the alkali hydroxide at the cathode.
Typically, sodium hydroxide is delivered in 30-40 % NaOH concentrations to customers, who will further dilute it for use at concentrations of 14-15 % NaOH.
These specific concentration percentages are obtained by mixing a full-strength solution with water.
Sodium Hydroxide (NaOH), Brine (NaCl), Hydrochloric Acid (HCl), Sodium Hypochlorite (NaClO):
Vaisala Polaris™ Process Refractometers are used to measure the concentration at different phases of the process. The first and the second measurements before the electrolytic cell, and in brine recirculation line, are NaCl measurements. Prior to the cell, the concentration varies between 250-320 g/l and the temperature between 50-70 ºC (122-158 ºF). In the recirculation line the numbers are 190-210 g/l and 70-90 ºC (158-194 ºF), respectively.
The third measurement is a hydrogen chloride (HCl) measurement. The concentration is 30-35 % and the temperature is ambient. A sulfuric acid concentration of 88-98 % is measured before feeding the product to the dryer at ambient temperature.
Sodium hydroxide measurements are taken prior to and after the evaporators. The pre-evaporator concentration is 25-35 % and after 45-55 %. The temperature decrease is from 70-90 ºC (158-194 ºF) to 30-50 ºC (86-122 ºF).
The last measurement is of NaClO, where the concentration is 0-12 % at ambient temperature.
The refractometer wetted parts are either plastic or metal alloys, depending on corrosion resistance requirements.
Several choices of refractometer wetted parts material are available for sodium chloride measurements, such as titanium or palladium doped titanium. For HCl the selection of material options includes tantalum, zirconium and chemically resistant Teflon body (PR53M) and Sounders body (PR53W) to ensure a viable service life.
It is the user’s responsibility to select the product wetted parts material, and to ensure that the material is satisfactory for the intended service conditions.

The Vaisala Polaris PR53M PTFE-Body Process Refractometer is for chemically aggressive solutions and ultra-pure fine chemical processes. The PR53M can be mounted to ½ inch process lines with a standard NTP-threaded connection, or optional pillar or flare fittings.
Vaisala Polaris PR53W Process Refractometer (pictured) is designed to measure concentrations of aggressive chemicals. The PR53W is mounted in a membrane-lined valve body that has no metallic wetted parts. This allows convenient flange mounting to 2-inch ANSI, DN50, or JIS 50A flanges.
The Vaisala Polaris PR53GP Process Refractometer is a heavy-duty instrument with non-weld body construction for diverse applications. The PR53GP can be installed directly into a tank or large pipelines, using either a standard ANSI, DIN or JIS flange connection, or clamp connection.
User Interface
Vaisala Polaris process refractometers are compatible with the Indigo platform, offering plug-and-play connectivity, user-friendly interfaces and service and configuration tools. The Indigo520 transmitter adds a physical user interface, data logging, advanced diagnostics, automatic wash control, and access to measurement settings and parameters.
Measurement range
Refractive Index (nD) 1.3200 – 1.5300, corresponding to 0-100 % by weight.

for cleanrooms and industrial settings

para secadores refrigerantes

para aplicaciones de fabricantes de equipos originales

para inspecciones rápidas y comprobación de errores

Transmisores de ±1,5 % HR para HVAC exigentes, con certificado

El calibrador de humedad HMK15 de Vaisala hace que la calibración y el control de punto de las sondas de humedad y transmisores sea fácil y confiable.

Principio de funcionamiento de los sensores infrarrojos, compensación por temperatura, presión y humedad, y ubicación de transmisores.

Por qué el CO2 es crítico en el cultivo celular, el riesgo de condensación al medir en alta humedad y temperatura, y por qué la esterilización sin…

Por qué se reduce el O2 y se eleva el CO2 en cámaras de atmósfera controlada, y qué instrumentos toleran el frío y la humedad elevada de este entorno.

Qué es el muestreo por equilibrio, por qué el calefaccionado del sensor puede alterar la medición en el campo, y qué rango se necesita para perfiles…
Un especialista responde con la solución, el instrumento y el servicio que corresponden.
Instrumentos para cotizar
Todavía no hay instrumentos. Se puede escribir igual: un especialista responde.