Current Good Manufacturing Practice (CGMP), according to the FDA's Code of Federal Regulations Title 21, requires that environments used to manufacture or process drug products be validated to ensure a high degree of quality and efficacy. Each firm is responsible for selecting suitable equipment used in research and development, manufacturing, or storage to produce quality products in accordance with CGMP.
Handling of equipment, calibration, maintenance, including temperature and/or humidity mapping, qualification, or validation of storage environments must be performed to ensure conditions match the stability requirements of the products. This is also a requirement as per international standards to ensure that the products are always stored and distributed within the specified temperature limits.
To ensure and demonstrate that proper environmental conditions and temperature and /or humidity controls are obtained, qualification and/or validation is expected to be carried out. Temperature Mapping studies must be carried out regularly as part of the equipment installation and operational qualification (IOQ) to ensure that an environmental room or controlled temperature chamber is capable of accurate and repeatable performance.
A properly developed qualification protocol will help ensure that the equipment meets all documentation requirements and performs as expected, including the temperature mapping study is correctly carried out. A trusted validation service provider can work with you to determine whether your qualification protocol is sufficient or help you generate a protocol to meet your requirements.
Generally, a protocol contains a documented approach to conduct the qualification process along with the procedure, scope, equipment description, responsibilities, test method, IQ/OQ/PQ test scripts, acceptance criteria, report and approval.
Since these concepts are not entirely always clear, the ISPE Good Practice Guide: Controlled Temperature Chambers – Commissioning and Qualification, Mapping and Monitoring (Second Edition) provides guidance on commissioning and qualification, temperature mapping, periodic reviews and also provides examples and sample templates.
Here is a list of what a basic temperature mapping protocol should contain:
The goals of the qualification and mapping study’s can be summarized as:
Prior to performing a qualification or requalification on any controlled temperature unit, ensure you have all documentation required to meet the manufacturer and site requirements. It’s recommended to physically see the unit prior to starting any documentation to ensure that all the supplies/materials are all accounted for in order to meet the site requirements.
By following the steps listed above, you will be on your way to successfully completing a temperature mapping study and well prepared for your next qualification.
Connect with Nathan Roman on LinkedIn
Vaisala Mapping Service is offered in Great Britain, Europe, and Japan.
See how simple vLog software validation is in our vLog Installation/Operational protocol sample.
Trusted Validation/Qualification Service Providers in America
In North Americas, these services can be provided by trusted providers in CQV who use Vaisala solutions.
“Everybody knows what needs to be done, but they’re not always sure how to get there. We know how to get there because that’s what we do, over and over again. We do things in ways that have been proven to be effective. We look at a process or system based on its objective, then we guide our clients to better solutions. Once I discovered the Vaisala data loggers and the vlog software, we saved a ton of time on mapping applications…”
- Nathan Roman, Director Validation Services, Genesis AEC
Learn about services from Genesis AEC services
“The vLog software is extremely easy to use. The system is comparatively user friendly and much simpler than any of the other systems we’ve tried. The batch setup feature is a huge time saver when using a large number of loggers and the graphs and reports are easily configurable to meet our needs. We recently had one large pharmaceutical customer who had experienced some issues with a non-Vaisala thermal validation system. The company had concerns with the accuracy of the devices and quality of the calibrations and documentation. They made an internal decision to use only Vaisala data loggers for thermal validation.”
- Neil Enlow, Principal Engineer with Performance Validation
Learn about services from Performance Validation
References:
Industry Guidelines:
There are many guidelines currently available on controlled temperature units and mapping guidelines.

Upper air soundings provide the crucial data necessary for a complete atmospheric weather profile that leads to accurate forecasting. However…

Vaisala Automatic Weather Station AWS310 is a complete communication and weather observation solution that can be used as a standalone unit, or as…

Our next-generation, cyber secure and modular Maritime Automatic Weather Station AWS830 is engineered for harsh marine environments and compliant…

The Vaisala Automatic Weather Station AWS810 enables modern, high-quality surface weather observation networks anywhere in the world.

Vaisala Maritime Automatic Weather Station AWS830 delivers accurate, always‑on weather, environmental, oceanographic, and motion data for demanding…

Vaisala Beam Weather Station BWS500 is a compact, scalable station for weather, air quality and road condition data, from a single standalone station…

La Punto de Rocío y Temperatura DMP5 Vaisala DRYCAP® está diseñada para la medición de humedad en línea en aplicaciones de secado industrial con…

El Dr. Lauri Reuter es una experta en el futuro de los alimentos y la persona a quien preguntar si alguna vez te has preguntado qué vamos a comer en…

Las empresas industriales continúan tomando medidas para minimizar sus emisiones de carbono. Muchos están reduciendo el uso de combustibles fósiles y…

En el proceso de caustificación, los químicos pasivos se convierten en químicos de cocina activos para producir licor blanco. Se utiliza en el…
Un especialista responde con la solución, el instrumento y el servicio que corresponden.
Productos para cotizar
Todavía no hay productos. Se puede escribir igual: un especialista responde.