Una unidad de AKRIBIS One

lws-rlpc-Series

Remote liquid particle counters (LPC)

Our comprehensive line of Remote Liquid Particle Counters will provide you the continuous monitoring data you are looking for. Our Remote Liquid Particle Counters will help you determine the DI Water being supplied to your process always maintains a certain level of cleanliness. These units can be easily set up into Facility Monitoring Systems and can also be easily cleaned and maintained.

Solicitar cotizaciónDescargar ficha técnica

Remote liquid particle counters (LPC)

Description

Continuous Monitoring for your DI Water System

Remote LPC 0.1µm (0.1 – 1.0μm Particle Size Range, 100mL Flow Rate) — key features

  • 0.1 – 1.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 2 channels of simultaneous data
  • 4-20mA Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability
Remote liquid particle counters (LPC)

Communication Output Options

  • 4-20mA Output or Modbus

Remote LPC 0.2µm (0.2 – 2.0μm Particle Size Range, 100mL Flow Rate) — key features

  • 0.2 – 2.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 2 channels of simultaneous data
  • 4-20mA Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability
Remote liquid particle counters (LPC)

Communication Output Options

  • 4-20mA Output or Modbus

Remote LPC 0.3µm (0.3 – 1.0μm Particle Size Range, 100mL Flow Rate) — key features

  • 0.3 – 3.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 2 channels of simultaneous data
  • 4-20mA Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Communication Output Options

  • 4-20mA Output or Modbus

Remote LPC 0.5µm (0.5 – 5μm Particle Size Range, 100mL Flow Rate) — key features

  • 0.5 – 5 μm particle size ranges
  • 100 mL/min flow Rate
  • 2 channels of simultaneous data
  • 4-20mA Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Communication Output Options

  • 4-20mA Output or Modbus

Remote LPC LE 1.0 µm (1.0 – 200.0μm Particle Size Range, 30mL Flow Rate) — key features

  • Size ranges 1 – 50 µm; 1 -200 µm
  • 8 channel output by Modbus; 4 channel by 4-20mA
  • LED status indicators for power, service, sampling
  • Interfaces with facility monitoring systems
  • Compact size
  • Designed for reliability

Remote LPC 0.1 micron (MODBUS Output)

Incorporating the latest in laser optical particle counting technology and utilizing in-situ particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.1μm (Modbus Output) for continuous trouble-free operation.

This compact liquid particle counter provides versatile mounting options and can be installed where space is at a premium.

The Remote Liquid Particle Counter 0.1μm integrates seamlessly into large facility monitoring and management systems using RS-485 MODBUS.

Features

  • 0.1 – 1.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 4 channels of simultaneous data
  • RS-485 Modbus Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Technical details (Remote LPC 0.1 micron (MODBUS Output))

SpecificationLPC 0.1 μm (MODBUS)LPC 0.1 µm (4-20mA)LPC 0.2 μm (MODBUS)LPC 0.2 μm (4-20mA)LPC 0.3 μm (MODBUS)LPC 0.3 μm (4-20mA)LPC 0.5 μm (MODBUS)LPC 0.5 μm (4-20mA)
Size Range0.1 – 0.5 µm0.1 – 0.5 µm0.2 – 2.0 µm0.2 –2.0 µm0.3 – 3.0 µm0.3 – 3.0 µm0.5 – 100.0 µm0.5 – 100.0 µm
Channel SizesStandard: 0.1, 0.2, 0.3, 0.5 µmStandard: 0.1, 0.2μm; / Optional: 0.1, 0.3µm; 0.1, 0.5µmStandard: 0.2, 0.3, 0.5, 1.0μm; 0.2, 0.5, 1.0, 2.0μmStandard: 0.2, 0.3μm / Optional: 0.2, 0.5μm; 0.2, 1.0μm; 0.2, 2.0μmStandard: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 3.0μmStandard: 0.3, 0.5μm / Optional: 0.3, 0.7μm; 0.3, 2.0μm; 0.3, 3.0μmStandard: 0.5, 0.7, 1.0, 2.0μm; 0.5, 1.0, 2.0, 3.0μm; 0.5, 1.0, 2.0, 5.0μmStandard: 0.5, 1.0μm / Optional: 0.5, 2.0μm; 0.5, 5.0μm
Laser SourceLaser DiodeLaser DiodeLaser DiodeLaser DiodeLaser DiodeLaser DiodeLaser DiodeLaser Diode
Flow Rate100ml/min100ml/min100ml/min100ml/min100ml/min100ml/min100ml/min100ml/min
CalibrationNIST TraceableNIST TraceableNIST TraceableNIST TraceableNIST TraceableNIST TraceableNIST TraceableNIST Traceable
Data StorageRotating Buffer, 2000 Records-Rotating Buffer, 2000 Records-Rotating Buffer, 2000 Records-Rotating Buffer, 2000 Records-
Communication ModesRS-232 via RJ45 to PC, RS485/ModbusRS-232 via RJ45 to PC, 4-20mARS-232 via RJ45 to PC, RS485/ModbusRS-232 via RJ45 to PC, 4-20mARS-232 via RJ45 to PC, RS485/ModbusRS-232 via RJ45 to PC, 4-20mARS-232 via RJ45 to PC, RS485/ModbusRS-232 via RJ45 to PC, 4-20mA
LED IndicatorsPower, Service, SamplingPower and ServicePower, Service, SamplingPower, ServicePower, Service, SamplingPower, Service, SamplingPower, Service, SamplingPower, Service, Sampling
Supporting SoftwareLMS Express, Express RT and RT+, LMSNetLMS Express, Express RT and RT+, LMSNetLMS Express, Express RT and RT+, LMSNetLMS Express, Express RT and RT+, LMSNetLMS Express, Express RT and RT+, LMSNetLMS Express, Express RT and RT+, LMSNetLMS Express, Express RT and RT+, LMSNetLMS Express, Express RT and RT+, LMSNet
Concentration Limit64,000 counts/ml @ 5% Coincidence Error64,000 counts/ml @ 5% Coincidence Error4,000 counts/ml @ 5% Coincidence Error4,000 counts/ml @ 5% Coincidence Error4,000 counts/ml @ 5% Coincidence Error4,000 counts/ml @ 5% Coincidence Error4,000 counts/ml @ 5% Coincidence Error4,000 counts/ml @ 5% Coincidence Error
External Alarm OutputNormal Open Dry Contact Rated 0 – 60v AC/DC 1 AmpNormal Open Dry Contact Rated 0 – 60v AC/DC 1 AmpNormal Open Dry Contact Rated 0 – 60v AC/DC 1 AmpNormal Open Dry Contact Rated 0 – 60v AC/DC 1 AmpNormal Open Dry Contact Rated 0 – 60v AC/DC 1 AmpNormal Open Dry Contact Rated 0 – 60v AC/DC 1 AmpNormal Open Dry Contact Rated 0 – 60v AC/DC 1 AmpNormal Open Dry Contact Rated 0 – 60v AC/DC 1 Amp
EnclosureStainless SteelStainless SteelStainless SteelStainless SteelStainless SteelStainless SteelStainless SteelStainless Steel
Sample Inlet/Outlet Connection1/4" Flaretek™1/4" Flaretek™1/4" Flaretek™1/4" Flaretek™1/4" Flaretek™1/4" Flaretek™1/4" Flaretek™1/4" Flaretek™
Sample Temperature32 - 140°F (0 - 60°C)32 - 140°F (0 - 60°C)32 - 140°F (0 - 60°C)32 - 140°F (0 - 60°C)32 - 140°F (0 - 60°C)32 - 140°F (0 - 60°C)32 - 140°F (0 - 60°C)32 - 140°F (0 - 60°C)
Sample Pressure150 PSI150 PSI150 PSI150 PSI150 PSI150 PSI150 PSI150 PSI
Wetted Surface MaterialsQuartz, PTFE, PFAQuartz, PTFE, PFAQuartz, PTFE, PFAQuartz, PTFE, PFAQuartz, PTFE, PFAQuartz, PTFE, PFAQuartz, PTFE, PFAQuartz, PTFE, PFA
Power24V DC24V DC24V DC24V DC24V DC24V DC24V DC24V DC
Dimensions5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm]
Weight3.5 lbs (1.58 kg)3.5 lbs (1.58 kg)3.5 lbs (1.58 kg)3.5 lbs (1.58 kg)3.5 lbs (1.58 kg)3.5 lbs (1.58 kg)3.5 lbs (1.58 kg)3.5 lbs (1.58 kg)
Operating50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing
IncludedOperating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Cleaning BrushOperating Manual on CD; Power Supply; Flow Cell cleaning brush; Micro90® solution; tubing.Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning BrushOperating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® SolutionOperating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning BrushOperating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® SolutionOperating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning BrushOperating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution
OptionalPrinted Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT; LMSNet softwarePrinted Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket.Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet softwarePrinted Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket.Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet softwarePrinted Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket.Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet softwarePrinted Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket.

Remote LPC 0.1 micron (4-20mA Output)

The Remote Liquid Particle Counter 0.1μm integrates seamlessly into large facility monitoring and management systems using 4-20mA output.

  • 0.1 – 1.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 2channels of simultaneous data
  • 4-20mA Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Remote LPC 0.2 micron (MODBUS Output)

Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.2μm (Modbus Output) for continuous trouble-free operation.

The Remote Liquid Particle Counter 0.2μm integrates seamlessly into large facility monitoring and management systems using RS-485 MODBUS.

  • 0.2– 2.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 4 channels of simultaneous data
  • RS-485 Modbus Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Remote LPC 0.2 micron (4-20mA Output)

Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.2μm (4-20mA Output) for continuous trouble-free operation.

The Remote Liquid Particle Counter 0.2μm integrates seamlessly into large facility monitoring and management systems using 4-20mA output.

Remote LPC 0.3 micron (MODBUS Output)

Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.3μm (Modbus Output) for continuous trouble-free operation.

The Remote Liquid Particle Counter 0.3μm integrates seamlessly into large facility monitoring and management systems using RS-485 MODBUS.

  • 0.3– 3.0 μm particle size ranges
  • 100 mL/min flow Rate
  • 4 channels of simultaneous data
  • RS-485 Modbus Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Remote LPC 0.3 micron (4-20mA Output)

Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.3μm (4-20mA Output) for continuous trouble-free operation.

The Remote Liquid Particle Counter 0.3μm integrates seamlessly into large facility monitoring and management systems using 4-20mA output.

Remote LPC 0.5 micron (MODBUS Output)

Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.5μm (Modbus Output) for continuous trouble-free operation.

The Remote Liquid Particle Counter 0.5μm integrates seamlessly into large facility monitoring and management systems using RS-485 MODBUS.

  • 0.5– 100 μm particle size ranges
  • 100 mL/min flow Rate
  • 4 channels of simultaneous data
  • RS-485 Modbus Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Remote LPC 0.5 micron (4-20mA Output)

Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.5μm (4-20mA Output) for continuous trouble-free operation.

The Remote Liquid Particle Counter 0.5μm integrates seamlessly into large facility monitoring and management systems using 4-20mA output.

  • 0.5 – 100 μm particle size ranges
  • 100 mL/min flow Rate
  • 2 channels of simultaneous data
  • 4-20mA Output
  • Stainless Steel Enclosure
  • Status Indicators
  • Interfaces with Facility Monitoring Systems
  • Compact Size
  • Designed for Reliability

Configurar el equipo

Elija modelo, sondas y accesorios. Las combinaciones incompatibles se bloquean solas; el resto de las reglas se verifica al agregar el equipo a la cotización.

Documentos