Una unidad de AKRIBIS One

Model-471

Model 471 Simple Argon Apparatus

The Isotech Argon Triple Point Apparatus has been upgraded for greater automation, efficiency, and ease of use in realising the argon triple point.

Solicitar cotizaciónDescargar ficha técnica

Model 471 Simple Argon Apparatus

Features

  • Affordable
  • Robust and simple to use
  • Accurate to ±0.8mK - 4 hour plateau typical
Model 471 Simple Argon Apparatus

Description

Many laboratories use liquid nitrogen comparators, a low-cost but imperfect method. Liquid nitrogen’s boiling point is not on the ITS-90 scale and is below the argon triple point. This presents challenges, as standard platinum resistance thermometers (SPRTs) often contain a mix of argon and oxygen. At -195°C, the gas inside the SPRT can be under partial vacuum, affecting self-heating and increasing calibration uncertainties.

Previously, the high cost and complexity of argon triple point systems were barriers for many laboratories. Isotech has changed that with a simpler, more affordable solution featuring automated temperature control for easier operation.

Specifications

Model471
Temperature Range-189.3442°C
Plateau Duration4 Hours
DimensionsHeight 1500mm, Width 380mm, Depth 615mm
How to orderModel 471 Argon Triple Point Apparatus

Documentos

  • Mercury-Triple-Point-Apparatus

    Mercury Triple Point Apparatus

    The Isotech Model ITL-M-17725 apparatus is a self-contained, mechanically-refrigerated, system with a main well to house one mercury cell and two…

  • Slim-Fixed-Point-Cells

    Slim Fixed Point Cells

    The Isotech B8 30 130 Cell is small enough to fit into portable Dry Blocks such as the Venus and Europa models. For the larger blocks like the…

  • Model-465

    Three Zone High Temperature Furnace 465

    Whilst heat pipe furnaces offer the ideal environment to melt and freeze ITS-90 Fixed Points the temperature range is limited by fluid that flows…

  • SPRT-108462

    Copper Point SPRT Model 108462

    The ITS-90 specifies the SPRT to the freezing point of silver, 961.78°C. Thermocouples can be used beyond this temperature but it is difficult to see…

  • Annealing-Furnace

    Annealing Furnace

    The Annealing Furnace, model 414, is designed to heat, anneal and cool Standard Platinum Resistance Thermometers (SPRTs) prior to calibration. The…

  • ISOTowers-Series

    ISOTowers

    The most accurately defined temperatures are those defining points (fixed points) of ITS-90.

  • Heat-Pipe-Furnaces

    Dual and Heat Pipe Furnaces

    Isotech metrology furnaces have more than 35 years of proven use and are widely used by the worlds’ leading NMIs. For the optimal use of fixed point…

  • Water-Triple-Point-Cells

    Jarrett-Isotech Water Triple Point Cells

    Internationally proven water triple point standards The Water Triple Point is the most important fixed point in temperature metrology, and the only…