Una unidad de AKRIBIS One

TRU-937

TRU Model 937

The TRU 937 (Temperature Reference Unit) supplies a stable and accurate 0°C or elevated Reference Temperatures between 45°C and 70°C. It is a self-contained all solid state unit using peltier technology which provides maintenance free operation.

Solicitar cotizaciónDescargar ficha técnica

TRU Model 937

Features

  • Up to 100 Channels
  • Compact, Pre Wired Thermocouples
  • Operates in High Ambients
TRU Model 937

Description

The TRU 937 features rapid cool down from high ambient temperatures and is stable within 10 minutes from switch on.

An alarm will be activated should the reference temperatures deviate by more than the user definable span. Thermocouple Reference Junctions are located in a reference block and connected to their marked input and output terminals in an isothermal enclosure. The uniform temperature throughout the enclosure ensures that no thermoelectric EMFs are generated at the terminals.

One advantage of the TRU 937 is that the user need not be concerned with the supply and installation of reference junctions since it is only necessary to connect the thermocouple compensation cables to the input terminals and the measuring instrument to the output terminals of the TRU 937.

There are two models, the TRU 937/50 with up to 50 junctions with a single terminal cover door, and the TRU 397/100 which has doors on the front and rear, as shown in the photograph.

TRU Model 937

Specifications

Operating Temperature0°C (or 45° to 70°C)
Ambient Range2°C to 65°C
Stability±0.03°C, errors introduced by thermocouple loading can be removed by adjusting controller offset.
Stabilising Time10 minutes from 44°C
CapacityUp to 100 Double Junction Channels
Input/Output ConnectionsKlippon Terminals, type 1.5 AKZ
Alarm facilitiesNon-latching relay rated 5 Amps 240V
Power100 Watts typical 100-130 or 208-240 VAC 50/60Hz
DimensionsHeight 265mm Width 253mm Depth TRU 937/100 – 312mm. Depth TRU 937/50 – 230mm.
WeightTRU 937/100 – 11kg TRU 937/50 – 8kg
Accessories935-14-55 – Platinum Resistance Thermometer suits Block B2: Includes UKAS calibration at 0.01°C. 935-17-33 – Fan Filter-recommended for high dust environments.
How to orderTRU Model 937 – Normally uniquely specified for each order. Please discuss your exact requirements with us before ordering.

Documentos

  • Multi-Junction-Probes

    Multi Junction Laboratory Probes

    Probes are suitable for use with all Isotech thermocouple reference units or may be used with any other equipment including ice flasks and ice point…

  • Hotbox-830

    Hotbox Model 830

    The Hotbox is housed in a robust waterproof enclosure to IP66 incorporating bottom gland plate. Fixing lugs for wall mounting are provided. Easy…

  • TRU2-922

    TRU² Model 922

    Why use an external cold junction reference?

  • Isobox-842

    Isobox Model 842

    The function of this reference unit differs from other cased systems in that the temperature of the metal block in which the thermocouple and copper…

  • TRUrac-847

    TRUrac Model 847

    The TRUrac is a 0°C or elevated temperature thermocouple reference system mounted in a 19” chassis. It has been developed for situations where…

  • TRU-938

    TRU Model 938

    The TRU (Thermocouple Reference Unit) supplies a stable and accurate 0°C, or elevated reference temperature. It is a self-contained all solid-state…