Medidor de peróxido de hidrogênio vaporizado, umidade e temperatura HPP272
para processos de biodescontaminação
Nota técnica

Yes, and I happen to have here an HMK15 Vaisala salt calibrator that can be used for calibrating this HPP272 probe, as well as these other humidity products. For this, you will need a USB cable, a laptop, and the Insight PC software, which is available as a free download on our website. Sanna: So, like Joni said, that this is a good way to do on-site calibration for humidity and for vaporized hydrogen peroxide using this equipment. But naturally, you can also send your probe to Vaisala device for calibration. Joni: Another question was: How many sensors do I need in my isolator, especially if it’s a big isolator? So, the first consideration here is the temperature differences there are in the application. If you have a uniform temperature and good circulation in the application, then one probe is good enough. But if there are temperature differences, then you need to know the lowest temperature if you want to avoid condensation, and you will need a temperature sensor at that cold spot. In the webinar, we also cover this mixture dew point temperature, which is a very valuable parameter to have in this kind of application, because when the mixture of dew point temperature is close to the lowest temperature in your application, you are at risk of condensation. Sanna: Ok next question: Does the catalyzed H2O2 have an influence on the humidity measurement? Yes, it does. So if you have a catalytic HUMICAP® sensor and the vaporized hydrogen peroxide is catalyzed into water vapor and oxygen, then there is extra humidity that is seen by the sensor. This is taken into account by the HPP271 and HPP272 measurement algorithm. Joni: Another question was about the different methods of producing vaporized hydrogen peroxide. A person asked: Is the Vaisala sensor suitable for different vapor generator technologies, such as nebulization for example. The answer is yes. The HPP270 series of probes measures vaporized hydrogen peroxide is independent of how the hydrogen peroxide vapor is produced. Sanna: OK, and then there was a question how the HUMICAP® and PEROXCAP® sensors function in high humidity. In Vaisala we test our sensors extensively and the PEROXCAP® sensor is designed to function in high humidity, even if there is visible condensation on the walls. And Joni can explain this technology further… Joni: Yes, PEROXCAP® is designed to be used in condensing environments. The sensor is actually heated up. So even in condensing environment, the HPP270 probes are capable of measuring humidity levels and vaporized hydrogen peroxide. Sanna: The same applies to the HMP7 technology, it has a warmed probe for measuring humidity. We’ve covered all the questions that we received. But before we go, we will go over the different sensors we covered and how you select the right sensor according to your application’s environment. Joni: So the first question you need to ask is, does my application contain hydrogen peroxide vapor and if the answer is no, then you are free to choose from many of our humidity products. But if the answer is yes, you have hydrogen peroxide in your application, you would choose from the HPP270 series probes. Then you would ask: Do I want to control the decontamination process? And if the answer is no, then you need to decide, is this hydrogen peroxide ppm exposure regular or is the concentration is very low, roughly below four hundred ppm? If the answer is no, you are good with HUMICAP® sensors that are equipped with a catalytic layer on the sensor. But if the answer is yes, you would benefit from having the catalytic HUMICAP with the chemical purge function. But, back to the question of controlling the bio-decontamination process… if the answer is yes, you want to control the process, then the next question is: is there uncertainty due to temperature differences?If the answer is no, your application has a very stable temperature, then the HPP272 is good for that application. But if there is high variability in temperature, you would want additional temperature measurements and focus on the mixture dew point parameter, also measured with the HPP272. Thank you Joni! And thank you for joining us.
The full webinar can be viewed at any time.

para processos de biodescontaminação

O mais novo integrante da linha Indigo de transmissores e sondas, o Indigo80 é um coletor de dados e indicador portátil e compacto. Ideal para…

O mais novo integrante da linha Indigo de transmissores e sondas, o Indigo80 é um coletor de dados e indicador portátil e compacto. Ideal para…

com ±1,5% de precisão de umidade relativa para aplicações de volume exigente

Upper air soundings provide the crucial data necessary for a complete atmospheric weather profile that leads to accurate forecasting. However…

Vaisala Automatic Weather Station AWS310 is a complete communication and weather observation solution that can be used as a standalone unit, or as…

A sonda de temperatura e ponto de orvalho DMP5 Vaisala DRYCAP® foi desenvolvida para medição de umidade em linha em aplicações de secagem industrial…

Lauri Reuter é um especialista no futuro da alimentação e a pessoa certa para perguntar se você já se perguntou o que comeremos no futuro e como toda…

As empresas industriais continuam a tomar medidas para minimizar as suas emissões de carbono. Muitos estão a reduzir a utilização de combustíveis…

No processo de caustificação, os produtos químicos passivos são convertidos em produtos químicos ativos para cozinhar para produzir licor branco…
Um especialista responde com a solução, o instrumento e o serviço adequados.
Produtos para cotar