PR2000-1000-PSIA
PR2000 (PR2000-1000-PSIA)
The PR2000 is a pressure data logger with NPT fitting and LCD for real-time monitoring. Includes ISO17025 accredited calibration certificate.
Solicitar cotaçãoBaixar ficha técnica
PR2000-1000-PSIA
The PR2000 is a pressure data logger with NPT fitting and LCD for real-time monitoring. Includes ISO17025 accredited calibration certificate.
Solicitar cotaçãoBaixar ficha técnica
The PR2000 is a pressure data logger with an LCD and wall mounted universal power adapter. Available in 10 ranges, the PR2000 can adapt to any application and features a ¼ in. NPT fitting for quick connection.
The 8-button keypad and LCD provide convenient access to current statistics (min, max, average), recording status, display options and calibration information. With the ability to measure and record data up to 262,144 readings, the PR2000 has one of the largest memory capacities of any similar data logger on the market.
The PR2000 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
| Memory | 262,144 readings |
|---|---|
| Reading Rate | 1 reading every 2 seconds up to 1 reading every 24 hours |
| Baud Rate | 115,200 |
| Battery Life | 1 year battery life at 1 minute reading rate with display off, 30 days typical with continuous display use. Optional AC adapter available. |
| Material | Black anodized aluminum case/NPT Steel |
| Dimensions | 5.1 in x 4.8 in x 1.705 (130 mm x 122 mm x 43.3 mm) |
| Operating Environment | -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing |
| Required Interface Package | IFC200 |
| Approvals | CE |
| Pressure Sensor | Semiconductor (strain gauge) |
|---|---|
| Pressure Range | 0 to 30, 100, 300, and 500 PSIA/G; 0 to 1000 and 5000 PSIA |
| Pressure Resolution | 0 to 30: 0.002, 0 to 100:0.005,; 0 to 300: 0.02, 0 to 500: 0.05, 0 to 1000: 0.05; 0 to 5000: 0.2 |
| Pressure Calibrated Accuracy | 2 %FSR, 0.25 % at +25 °C (+77 °F) Typical |
Escolha modelo, sondas e acessórios. As combinações incompatíveis são bloqueadas na hora; as demais regras são verificadas ao adicionar o equipamento à cotação.
Carregando as opções…
É possível colar um código e a configuração se monta sozinha.
São cotados à parte: não é preciso configurar o equipamento.



Instrumentos para cotar
Ainda não há instrumentos. É possível escrever mesmo assim: um especialista responde.