Remote 1104 ™ (0.10 – 5.0 µm Particle Size Range, 1.0 CFM Flow Rate) — key features

  • 0.10 – 5.0 µm Sensitivity
  • 1.0 CFM (28.3 LPM) Flow Rate
  • Up to 8 Channels of Simultaneous Data
  • World’s Smallest 1.0 CFM 0.10 µm counter
  • Meets ISO 21501-4 Standards
  • Long Life Laser Diode
  • Small Footprint
  • Status Indicators
  • RS-485 MODBUS (R1100 Pulse output)
  • Stainless Steel Enclosure
  • Interfaces to Facility Monitoring Systems
  • Uses External Vacuum Source
  • Designed for Reliability
  • Designed to Ensure 21 CFR Part 11 Compliance when used with Additional Software
  • No Routine Laser Tube Replacements

Remote 5104V ™ (0.5 – 5.0 µm Particle Size Range, 1.0 CFM Flow Rate) — key features

  • VHP Compatible
  • Class 1 Division 2 Rating
  • Built-in Flow Monitoring
  • 0.5 – 5.0 µm
  • 1.0 CFM (28.3 LPM) Flow Rate
  • Up to 4 channels of simultaneous data
  • Meets ISO 21501-4 standards
  • Real-time continuous monitoring
  • Small size
  • 316L Stainless Steel, Wash Down Resistant / Splash-Tight Enclosure
  • Status Indicators
  • RS-485 Modbus
  • Interfaces to Facility Monitoring Systems
  • Uses External Vacuum Source
  • Designed for Reliability
Remote particle counters (1100LD, 1104LD, 5104V)

Remote 1104LD

Using state-of-the-art Long Life Laser Diode technology, the Lighthouse Remote 1104LD is an industry first- a laser diode-based remote particle counter with a sensitivity of 0.10 micron at a high flow rate of 1.0 CFM (28.3 LPM) that uses an optics and photodiode system designed to reduce or eliminate the temperature issues associated with high power laser diode sensors. Designed with reliability and quality in mind, the Remote 1104LD features our long-life laser diode technology that provides higher concentration limits, a better signal-to-noise ratio, and requires less routine maintenance than conventional HeNe laser-based particle counters. Very simple to integrate with large facility monitoring and management systems, the Remote 1104LD can transfer up to 8 channels of simultaneous particle count data via RS-485 MODBUS.

Key Features

Remote particle counters (1100LD, 1104LD, 5104V)

Technical details (Remote 1104LD)

Size Range0.10 - 1.0 μm | 0.2 - 2μm | 0.3 - 25μm | 0.5 - 25μm
Channel SizesStandard: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 μm | Standard: 0.2, 0.3μm / Standard: 0.2, 0.5μm / Optional: 0.2, 0.3, 0.5, 1.0μm / Optional: 0.2, 0.3, 0.5, 2.0μm | Standard: 0.3, 0.5μm / Standard: 0.3, 1.0μm / Standard: 0.3, 3.0μm / Optional: 0.3, 0.5, 1.0, 5.0μm | Standard: 0.5, 5.0μm / Optional: 0.5, 1.0, 5.0, 10.0μm / Optional: 0.5, 5.0, 10.0, 25.0μm | Standard: 0.3, 0.5μm / Optional: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 5.0μm; / Optional: 0.3, 0.5, 5.0, 10.0μm | Standard: 0.5, 5.0μm; 0.5, 10.0μm / Optional: 0.5, 1.0, 5.0, 10.0μm; 0.5, 5.0, 10.0, 25.0μm
Flow Rate1.0 CFM (28.3 LPM) | 0.1 CFM (2.83 LPM)
Laser SourceLaser Diode
Zero Count Level< 1 Count / 5 minutes (meets specifications of JIS B 9921 and reporting requirements of ISO 21501-4 Annex C)
Concentration Limits1,000,000 particles /ft3 (34,300,000/m3 ) @ 10% coincidence loss | 4,000,000 Particles/ft3@10% Coincidence loss suitable for ISO classes 1-8 cleanrooms | 1,000,000 Particles/ft3@10% Coincidence loss suitable for ISO classes 1-8 cleanrooms
CalibrationNIST Traceable ISO 21501-4 Compliant and Accredited ISO 17025
Vacuum RequirementsExternal Vacuum >18” (45.72 cm) of Hg
Air FlowInternally Monitored
Communication ModesSerial - 485 Modbus RJ45
LED IndicatorsPower, Flow, Service, Sampling
Data Storage999 records
Supporting SoftwareLMS XChange, Lighthouse Monitoring System; LMS Express; Express RT; LMSNet
Environmental Sensors- | (Optional) Temperature/Relative Humidity Probe 32 - 122F (0-50C)+/-1F (0.5C); 0 - 100% RH +/-2%
ConnectorRJ45 | Industrial RJ45
Power24 VDC
Dimensions10.5” (w) x 7.65” (h) x 3.35” (d) [26.67 x 19.43 x 8.51 cm] | 1.7”(l) x 4.2”(w) x 3”(h) [4.3 x 10.7 x 7.6 cm] | 1.7"(l) x 4.2"(w) x 3"(h) [4.3 x 10.7 x 7.6 cm] | 1.7”(l)x4.2”(w)x3”(h) [4.3x10.7x7.6cm] | 5.42” (l) x 2.14” (w) x 3.58” (h), [13.76 cm (l) x 5.43 cm (w) x 9.09 cm (h)]
Operating50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing

Remote 5104V

Compatible with VHP, the Remote 5104V meets the stringent requirements of today’s aseptic processing applications. In addition, the Remote 5104V was designed to operate in CLASS 1 DIV 2 hazardous environments found in many challenging applications.

The Remote 5104V uses a critical orifice and external vacuum source for flow control. Built-in flow monitoring assures accuracy and reliability of the sensor’s performance.

The Remote 5104V integrates seamlessly with large facility monitoring and building management systems. It transfers up to 4 channels of simultaneous particle count using RS-485 Modbus.

  • VHP Compatible
  • Class 1 Division 2 Rating
  • Built-in Flow Monitoring
  • 0.5 – 5.0 µm
  • 1.0 CFM (28.3 LPM) Flow Rate
  • Up to 4 channels of simultaneous data
  • Meets ISO 21501-4 standards
  • Real-time continuous monitoring
  • Small size
  • 316L Stainless Steel, Wash Down Resistant / Splash-Tight Enclosure
  • Status Indicators
  • RS-485 Modbus
  • Interfaces to Facility Monitoring Systems
  • Uses External Vacuum Source
  • Designed for Reliability
  • International Support

Remote 5104

Incorporating the latest laser optical particle counting technology, Lighthouse designed the Remote 5104 for continuous trouble-free operation.

Using an external vacuum source, the Remote 5104 provides versatile mounting options and can be installed where space is at a premium. The Remote 5104 will integrate seamlessly into extensive facility monitoring and management systems.

  • 0.5 – 25 µm Particle Size Range
  • 1.0 CFM (28.3 LPM) Flow Rate
  • 4 Channels of Simultaneous Data
  • RS-485 Modbus Output
  • Meets 21501-4 Standards
  • Status Indicators
  • External Alarm Output
  • Stainless Steel Enclosure
  • Facility Monitoring Systems Interface
  • Versatile Mounting Options
  • External Vacuum Source
  • Designed for Reliability

Configurar o equipamento

Escolha modelo, sondas e acessórios. As combinações incompatíveis são bloqueadas na hora; as demais regras são verificadas ao adicionar o equipamento à cotação.

Documentos