Spray solvent tools are used in the post etch residual polymer removal process to clean the surface of wafers. EKC is a commonly used chemical in the process that employs two tanks. The process operating temperature of EKC is kept between 65 °C (149 °F) and 75 °C (167 °F). The actual residue removal takes place in the spray solvent tool where EKC is fed to, according to a pre-determined cycle of chemical recirculation and wafer run.

Chemical curve: Water in EKC R.I. per Conc% b.w. at Ref. Temp. of 20˚C
Two control strategies can be adopted with the aid of Vaisala Polaris™ PR53S Semicon Process Refractometer. The first one is to monitor water content in EKC, and the second is to maintain the water content at a constant level. The former allows for setting high and low alerts for the amount of water, which warrants safe wafer production. The latter has proved to provide a considerable reduction in the EKC consumption.
The recirculation starts when the wafer run in the spray solvent tool is over and the chemical is delivered to the EKC tank. The tank is partially drained of the chemical and refilled with fresh EKC and water. Water is evaporating through the exhaust system of the spray solvent tool during the spray run.
The amount of water in EKC is maintained with automated chemical spiking after each wafer run. The chemical spiking is activated using the PR53S output signal. This arrangement provides the exact set point for water in the EKC concentration and helps to optimize and reduce EKC replenishment.

After EKC clean, there is an IPA/Dry process where IPA may get contaminated with EKC traces. The Semicon Refractometer can monitor the concentration of the chemicals to alert of possible mixes. The refractive index values of EKC and IPA differ substantially allowing a very reliable measurement of EKC traces in IPA.

The Semiconductor Refractometer PR53S is installed in the EKC recirculation loop. The compact instrument’s design suits the water level control for EKC perfectly. Data logging software allows on-line printing of concentration and temperature profiles.

A small footprint ultrapure inline refractometer for real-time chemical concentration measurement in semiconductor wet processes.
Designed with a modified PTFE flow cell and flexible ¼–1 inch pillar or flare connections, the PR53S integrates seamlessly into wet benches, chemical distribution systems, and process tools.
Measurement range
Refractive index (nD) 1.3200 - 1.5300, corresponding to 0-100% by weight.

para aplicaciones de fabricantes de equipos originales

Tenga en cuenta que el DMT152 se está descontinuando y no debe especificarse para nuevos proyectos. Conozca el nuevo DMT153 aquí.

con ±1,5 % HR Precisión para aplicaciones de volumen exigentes

con ±1,5 % HR Precisión para aplicaciones de volumen exigentes

con ±1,5 % HR Precisión para aplicaciones de volumen exigentes

Los transmisores Indigo300 son dispositivos host para sondas inteligentes, independientes y compatibles con Indigo de Vaisala. Los transmisores…

Principio de funcionamiento de los sensores infrarrojos, compensación por temperatura, presión y humedad, y ubicación de transmisores.

Por qué el CO2 es crítico en el cultivo celular, el riesgo de condensación al medir en alta humedad y temperatura, y por qué la esterilización sin…

Por qué se reduce el O2 y se eleva el CO2 en cámaras de atmósfera controlada, y qué instrumentos toleran el frío y la humedad elevada de este entorno.

Qué es el muestreo por equilibrio, por qué el calefaccionado del sensor puede alterar la medición en el campo, y qué rango se necesita para perfiles…
Un especialista responde con la solución, el instrumento y el servicio que corresponden.
Instrumentos para cotizar
Todavía no hay instrumentos. Se puede escribir igual: un especialista responde.