Gas Detectors E2611
2 × SPST relays, 2×4-20mA/0-10V, RS485 Modbus RTU, slotted ABS 85 × 85 × 37 mm, IP20
E2648
transmitter only (optional relays), 2 × 4-20mA/0-10V, RS485 Modbus RTU, grey die-cast aluminium 120 × 125 × 57 mm, IP66
Solicitar cotizaciónDescargar ficha técnica
transmitter only (optional relays), 2 × 4-20mA/0-10V, RS485 Modbus RTU, grey die-cast aluminium 120 × 125 × 57 mm, IP66
| Power supply | 12...36 VDC (default),; 24 VAC or 230 VAC as options |
|---|---|
| Digital interface | RS485, Modbus RTU protocol |
| Analog outputs | 2 × 4-20 mA / 0-10 V, user settable |
| Dimensions | H120 × W125 × D57 mm |
| Model | Gas | Sensor type | Sampling method | Detection range | Resolution | Sensor lifetime | Output relays (option) | Enclosure | Operating conditions | Default alarm set-points |
|---|---|---|---|---|---|---|---|---|---|---|
| E2648-C2H4 | ethylene C2H4 | electrochemical | diffusion | 0...10 ppm C2H4 0...200 ppm C2H4 0...1500 ppm C2H4 | 0,1 / 1 / 1 ppm C2H4 | 2 years | 2 × SPST relays (closing contact), | die-cast aluminium, wall mount, IP66 | -40...+50 °C, 15...90 %RH | |
| E2648-CH4 | methane CH4 | metal-oxide semiconductor (MOS) pellistor (catalytic bead) on demand | diffusion | 0...100% LEL CH4 | 0,1 / 1 %LEL CH4 | > 5 years (MOS) > 3 years (pellistor) | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -40...+70 °C, 15...95 %RH (MOS) -10...+50 °C, 0...95 %RH (pellistor) | 20% LEL / 50% LEL CH4 |
| E2648-CL2 | chlorine Cl2 | electrochemical | diffusion | 0...10 ppm Cl2 | 0,1 ppm Cl2 | 2 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -20...+50 °C, 15...90 %RH | 0,5 ppm / 1 ppm Cl2 |
| E2648-CO | carbon monoxide CO | electrochemical | diffusion | 0...300 ppm CO 0...1000 ppm CO | 1 ppm CO | > 10 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -20...+50 °C, 15...90 %RH | 25 ppm / 35 ppm CO |
| E2648-CO2 | carbon dioxide CO2 | photoacoustic optical NDIR | diffusion | 0...10 000 ppm (10K) CO2 0...40 000 ppm (40K) CO2 0...5 %vol (50KN) CO2 up to 100 %vol CO2 on request | 1 ppm for 10K 10 ppm for 40K 0.01%vol for 50KN | up to 10 years for 10K/40K up to 5 years for 50KN | 2 × SPST relays (closing contact), | die-cast aluminium, wall mount, IP66 | -40...+60 °C, 0...100 %RH | |
| E2648-ETO | ethylene oxide C2H4O | electrochemical | diffusion | 0...20 ppm C2H4O 0...100ppm C2H4O | 0,1 ppm C2H4O for 20 ppm range 1 ppm C2H4O for 100 ppm range | 2 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -20...+50 °C, 15...90 %RH | |
| E2648-H2S | hydrogen sulfide H2S | electrochemical | diffusion | 0...100 ppm H2S 0...2000 ppm H2S other ranges on request | 0.1 / 1 ppm H2S | > 2 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -30...+50 °C, 15...90 %RH | 10 ppm / 20 ppm H2S |
| E2648-HFC | R-32, R-134a, R-404A, R-407C, R-410A, R-449A, R-454A, R-454B, R-454C, R-507, R-513A, R-1234ze, etc. | metal-oxide semiconductor optical NDIR on demand | diffusion | 0...1000 ppm halocarbon gas 0...2500 ppm halocarbon gas | 1 ppm halocarbon gas | > 5 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -30...+60 °C, < 95 %RH | minimum 250 ppm |
| E2648-LEL | methane CH4 | metal-oxide semiconductor (MOS) pellistor (catalytic bead) on demand | diffusion | 0...100% LEL | 0,1 / 1 % LEL | > 5 years (MOS) > 3 years (pellistor) | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -40...+70 °C, 15...95 %RH (MOS) -10...+50 °C, 0...95 %RH (pellistor) | 20% LEL / 50% LEL CH4 |
| E2648-N2O | nitrous oxide N2O | optical NDIR | diffusion | 0...1000 ppm N2O | 1 ppm N2O | up to 5 years | 2 × SPST relays (closing contact), | die-cast aluminium, wall mount, IP66 | -20...+50 °C, 0...95 %RH | |
| E2648-NH3-E | ammonia NH3 | electrochemical | diffusion | 0...100 ppm NH3 0...300 ppm NH3 0...1000 ppm NH3 0...5 000 ppm NH3 up to 10000 ppm on request | 1 ppm NH3 | > 2 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -40...+50 °C, -30...+50°C (for 0...5 000 ppm), 15...90 %RH | 25 ppm / 35 ppm NH3 |
| E2648-NH3-P | Ammonia NH3 | Pellistor (catalytic bead) | Diffusion | 0...15% vol. (0…100% LEL) | 0.1% vol. or 1% LEL | > 3 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | Die-cast aluminum, wall mount, IP66 | -10...+50 °C, 0...95% RH | |
| E2648-NO | nitric oxide NO | electrochemical | diffusion | 0...250 ppm NO | 1 ppm NO | > 12 months | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -30...+50 °C, 15...90 %RH | 10 ppm / 25 ppm NO |
| E2648-NO2 | nitrogen dioxide NO2 | electrochemical | diffusion | 0...20 ppm NO2 0...200 ppm NO2 | 0,1 ppm NO2 for 20 ppm range 1 ppm NO2 for 200 ppm range | > 2 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -20...+50 °C, 15...90 %RH | 3 ppm / 6 ppm NO2 |
| E2648-O2 | Oxygen O2 | Electrochemical | 0...25 %vol O2 | 0,01 %vol O2 | > 2 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, protection class IP66 | -30...+50 °C, 15...90% RH, no condensation | ||
| E2648-O3 | ozone O3 | electrochemical | diffusion | 0...5 ppm, 0...1 ppm | 0,01 ppm | > 2 years (0...5 ppm) > 18 months (0...1 ppm) | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -40...+50 °C (0...5 ppm), -20...+40 °C (0...1 ppm), 15...90 %RH | |
| E2648-PID | isobutylene | Photo Ionization Detector | diffusion | 0...40 ppm isobutylene 0...200 ppm isobutylene | 0,01 ppm C4H8 for 40 ppm range 1 ppm C4H8 for 200 ppm range | 5 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -40...+55 °C, < 95 %RH | |
| E2648-SO2 | sulfur dioxide SO2 | electrochemical | diffusion | 0...50 ppm SO2 0...2000 ppm SO2 | 0,1 ppm SO2 for 50 ppm range 1 ppm SO2 for 2000 ppm range | > 2 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -30...+50 °C, 15...90 %RH | |
| E2648-VOC | toluene | metal-oxide semiconductor | diffusion | 0...100% LEL (flammable range) 0...1000 ppm (toxic range) | 0,1% LEL for LEL range 1 ppm for ppm range | > 5 years | 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max | die-cast aluminium, wall mount, IP66 | -30...+70 °C, < 95 %RH | 20% LEL / 50% LEL 100 ppm / 300 ppm |
Elija modelo, sondas y accesorios. Las combinaciones incompatibles se bloquean solas; el resto de las reglas se verifica al agregar el equipo a la cotización.
Cargando las opciones…
Se puede pegar un código y la configuración se arma sola.
Se piden por separado: no hace falta configurar el equipo.

2 × SPST relays, 2×4-20mA/0-10V, RS485 Modbus RTU, slotted ABS 85 × 85 × 37 mm, IP20

2 × SPDT relays, slotted ABS 85 × 85 × 37 mm, IP20, LEDs, buzzer, 24 VDC / 24 VAC / 230 VAC


transmitter only, 2×4-20mA/0-10V, RS485 Modbus RTU, grey ABS 80 × 82 × 55 mm, IP65

2 x SPDT relays, ABS plastic 90 x 145 × 55 mm, IP65, LEDs, buzzer, 24 VDC / 24 VAC / 230 VAC

transmitter only, 2 x 4-20 mA / 0-10 V, RS485 Modbus RTU, grey ABS 90 × 145 × 55 mm, IP65

transmitter only (optional relays), 2 × 4-20mA/0-10V, RS485 Modbus RTU, grey ABS 90 × 145 × 50 mm, IP65

E2639 is a member of the new-generation PluraSens® family of multifunctional measurement instruments.

The instrument utilizes novel fully calibrated and temperature compensated gas sensors with excellent repeatability, stability, and long lifetime.

Instrumentos para cotizar
Todavía no hay instrumentos. Se puede escribir igual: un especialista responde.