Una unidad de AKRIBIS One

microsKanner-913-HC

913-HC microsKanner

The microsKanner can be used with any member of the microK family to add further channels, up to a maximum of 90 expansion channels. It is now available as the enhanced Model 913-HC, recommended for use with all microK and microK² instruments. The 913-HC increases the maximum sensor current to 14.2 mA when used with a microK² and features updated styling to complement the latest microK design. It provides the same zero-uncertainty performance as the original 913, while offering improved capabili

Solicitar cotizaciónDescargar ficha técnica

913-HC microsKanner

Features

  • Expandable to 90 channels
  • Supports PRTs, thermocouples & thermistors
  • Plug-and-play operation
913-HC microsKanner

Description

Easy to Use
Plug-and-play operation means that additional channels appear automatically on the microK when a microsKanner is connected. New inputs can be configured in exactly the same way as the microK’s existing channels, whether through the touchscreen or via a PC using an RS232 connection. Simply connect a microsKanner and the extra channels are immediately available, making this one of the most straightforward expansion systems of its kind.

Accurate
The microsKanner replicates the input architecture of the microK bridge across all ten of its channels. Measurements made through a microsKanner therefore have the same accuracy as those made directly on the microK. Additional scanners can be added to expand a system to 92 channels without introducing additional measurement uncertainty.

Specifications

ModelmicrosKanner
Channels10
Keep-warm-currents0-14.2mA ±0.4% of value, ±7μA, resolution 2.5μA
Input ConnectorsCable Pod connector accepting: 4mm plugs, spades or bare wires.
Contact MaterialGold-plated tellurium copper
InterfaceRS232 (9600 baud)
Operating Conditions15-30°C / 50-85°F, 10/90% RH (for full application) 0-50°C/ 32-120°F, 0-99% RH (operational)
Power88-264V (RMS) 47-53Hz (universal) 10 Watts maximum, 1.2A (RMS) Maximum.
Size520mm x 166mm x 300mm / 20.5
Weight12.6kg / 28lb

Documentos

  • TC-Fixed-Resistors

    Temperature Controlled Fixed Resistors

    By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a…

  • Standard-Resistor-Bath

    Standard Resistor Maintenance Bath

    This bath is the result of many years of development and is used to maintain the temperature of standard resistors used with thermometry bridges. It…

  • Standard-Resistors

    Standard Resistors

    Eventually all resistance thermometry refers back to one or more fixed resistors. These are a key element in any laboratory which measures…

  • RBC

    RBC Resistance Bridge Calibrators

    Operating principles The problem: Temperature measurement is one of the most demanding applications of resistance measurement. It requires the…

  • microK2

    microK² Precision Thermometry Bridge

    The microK² builds on the success of the original microK models that were quickly adopted by leading National Metrology Institutes and commercial…