Una unidad de AKRIBIS One

Standard-Resistors

Standard Resistors

Eventually all resistance thermometry refers back to one or more fixed resistors. These are a key element in any laboratory which measures temperature. The resistors need to be very stable with time, temperature and transportation, and they need to have negligible inductance and capacitance.

Solicitar cotizaciónDescargar ficha técnica

Standard Resistors

Description

They also need to have a long and successful history of use. Wilkins and Swan at our National Physical Laboratory (NPL) developed a resistor design flexible enough to allow windings with various resistance values to be made available and stable enough to be accepted world-wide as resistance standards. Particularly important is that the AC/DC characteristics are the same up to about 1000 Hz.

This design has been licensed to H. Tinsley & Co. who have been producing (and have made further improvements to) this product since 1970. Isotech are pleased to be able to offer this design of resistor made for us by Tinsley with 1 of 2 calibration possibilities:

UKAS with an uncertainty of ±0.3ppm (SRA models). NPL with an uncertainty of ±0.1 ppm (dependent on resistance value).

Standard Resistors

Specifications

Type SRA Values1, 10, 25, 100 Ohms, 400 Ohms to special order
Type SRB Values1000 10,000 Ohms
Calibrated Uncertainty0.3ppm (see UKAS schedule)
Accuracy of Adjustment±20ppm
Stability2ppm/year (0.5ppm/ year to special order)
Temperature coefficient of resistance2ppm / °C 0.5ppm made to special order
Recommended Dissipation10 mW
Maximum Dissipation1 Watt
Approximate load coefficient6ppm/ Watt
A.C./D.C. transfer error at 1kHz1ppm 10Ω – 10kΩ. 5ppm – 1Ω

Construction:

ElementStrain free, immersed in dry oil (no. 4 Kerosene)
Top PanelBakelite with PFTE inserts and engraved lettering
Terminal – current0BA Copper
Terminal – Potential4BA Copper
Earth6BA Brass
DimensionsContainer 114 x 74mm dia. Overall 140 x 83mm dia.
Weight680g
How to orderStandard resistor. Please specify type, resistance value and calibration option.

Documentos

  • RBC

    RBC Resistance Bridge Calibrators

    Operating principles The problem: Temperature measurement is one of the most demanding applications of resistance measurement. It requires the…

  • microsKanner-913-HC

    913-HC microsKanner

    The microsKanner can be used with any member of the microK family to add further channels, up to a maximum of 90 expansion channels. It is now…

  • TC-Fixed-Resistors

    Temperature Controlled Fixed Resistors

    By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a…

  • microK2

    microK² Precision Thermometry Bridge

    The microK² builds on the success of the original microK models that were quickly adopted by leading National Metrology Institutes and commercial…

  • Standard-Resistor-Bath

    Standard Resistor Maintenance Bath

    This bath is the result of many years of development and is used to maintain the temperature of standard resistors used with thermometry bridges. It…