Simple Nitrogen Boiling Point Apparatus Model 461
This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar…
Saturn-877
The Saturn spherical furnace comprises a number of concentric shells. The outer shell of spun metal is for containment and support. Inside this is a layer of ceramic fibre. Within the fibre is a ceramic spherical mantle containing the heater windings. In the centre of the furnace is a solid cast ceramic sphere with 8 or 16 tubes, to be used for the thermocouples requiring calibration.
Solicitar cotizaciónDescargar ficha técnica

Isotech’s calibration furnace is revolutionary from a number of aspects:
It is spherical, and its design ensures a central zone of constant temperature.
Thermocouples are inserted around the circumference of the furnace. When fully inserted the measuring junctions are within a few millimeters of each other at the centre of the sphere.
Up to 15 thermocouples can be calibrated simultaneously. The accuracy is between ±0.25°C and ±0.1°C at 1000°C.
Larger tube diameters will give larger gradients, as will larger numbers of tubes. The precision of this furnace has previously been achieved only by using heat pipes. Because of the design the price is only one half to one third that of a bath with comparable accuracy and much smaller capacity of calibration.
The use of newly developed modern ceramic materials has enabled high accuracy, low mass and high stability to be obtained. The Saturn system will not contaminate your thermocouples unlike some furnaces that have metal equalising blocks.

| Model | 877 |
|---|---|
| Temperature Range | 100°C to 1300°C |
| Number of Calibration Points | 8 as standard, 16 to special requirements |
| Diameter of sensors | 4 x 6mm + 4 x 8mm |
| Depth of Immersion | 180mm |
| Accuracy | ±0.25°C to ±0.1°C at 1000°C (using comparison techniques) |
| Warm-up Times* | 1 hour to 700°C 3 hours to 1300°C |
| Stabilisation Time* | 1 hour to ±0.25°C |
| Power | 3kW, 208-240Vac, 50/60Hz 3kW 115Vac, 50/60Hz |
|---|---|
| Dimensions | 425mm Diameter, weight 25kgs |
| Accessories | 877/01 Equalising Block 4 x 8mm + 4 x 6mm i.d. (standard), 877-01S Equalising Block 16 x 6mm (special), 877/01E Equalising Block – other configurations (contact Isotech) – 877/02 Platinum Foil Temperature Barrier. |
| How to order | 877 Thermocouple Calibration Facility including Standard Equalising Block. Please specify voltage needed. |

This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar…

The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. The Orion range has been introduced to fit…

Isotech calibration baths employ sophisticated designs to ensure calibration to the smallest of uncertainties. In 1986 Isotech purchased the…

The Model 547 is the professional solution for accurate and contamination-free temperature calibration, designed to meet the needs of professionals…

Isotech Nitrogen Boiling Point Apparatus is designed specifically to realise and maintain the liquid/vapour equilibrium (boiling point) of nitrogen…

This economically-priced Standard Platinum Resistance Thermometer, Model 909, is the workhorse of calibration laboratories all over the world. During…

When we considered low temperature comparison calibration, we had to take into account Health and Safety considerations, both of the liquids used in…
Instrumentos para cotizar