Features

  • Multi Function: Six Modes including Dry Block and Liquid Bath
  • Fast Response 35mm x 160mm Calibration Volume
  • Calibrate Whole Measurement Loop
  • OTI/WTI Calibratior
Venus 4951

Description

  • Multi Function: Six Modes including Dry Block and Liquid Bath
  • Fast Response 35mm x 160mm Calibration Volume
  • Calibrate Whole Measurement Loop

These models will calibrate temperature probes from -45°C to 250°C with unrivalled flexibility. As a traditional Dry Block, several thermometers can be quickly calibrated.

One application for the Venus Site is for the calibration of oil temperature indicators (OTI) and Winding Temperature Indicators (WTI) in power generation, transmission and distribution.

Accessories are available to convert to a stirred liquid bath, for surface sensor calibration, to calibrate infrared thermometers and even to use as an ITS-90 Fixed Point System with calibration uncertainties as small as 0.0005°C. With excellent stability and distributed heating cooling zones for good uniformity these calibrators offer proven thermal performance.

Venus 4951

These award winning calibrators are easy to use and are available in three versions – the Basic, the Site and the ADVANCED. The Basic has a digital display of set and nominal temperature, the Site additionally includes an inbuilt independent temperature indicator for a reference probe. The ADVANCED controller has inputs for reference and test thermometers with a further range of sophisticated features including automatic temperature cycling, secure data logging and full colour high resolution display.

All models include I-Cal Easy LOG software and the ADVANCED models additionally include software to manage logged data and configure the unit, more details.

These models meet the calibration capacity requirements of EURAMET calibration Guide 13 “EA Guidelines on the Calibration of Temperature Block Calibrators”

Venus 4951

Specifications

Temperature Range*-35°C to 140°C

ADVANCED Range

Stability: Dry Block / Liquid Bath±0.01°C
Display Resolution0.001°C over whole range
Input Channel Accuracy: ThermocoupleE, J, K, N ±0.2°C @ 660°C R: ±0.6°C S: ±0.7°C @ 660°C T: ±0.2°C @ 150°C
CJC Accuracy±0.35°C
Input Channel Accuracy: RTD±0.10°C across range

BASIC / SITE Range

Stability±0.03°C
Display Resolution0.01°C from -19.99 to 99.99°C then 0.1°C: 0.01°C Over PC Interface

COMMON Specifications

StabilityBlackbody ±0.03°C Surface Sensor ±0.5°C ITS-90 Cells ±0.0005°C
Uniformity – Between Wells Dry Block Mode (Radial)<0.008°C
Uniformity – Lower 40mm (Axial) Dry Block Mode<0.040°C
Uniformity – Radial Bath Mode<0.02°C
Uniformity – Lower 40mm (Axial) as Liquid Bath<0.026°C
Heating Time-30°C to 140°C: 15 mins
Cooling Time140°C to 0°C: 15 mins
Calibration Volume35 x 160mm
Standard Insert6 pockets, 2 x 4.5mm, 2 x 6.4mm, 1 x 8.0mm, 1 x 9.5mm diameter, all 157mm deep
Insert TypesChoice of three – See Accessories
CJC Accuracy0.35°C
Dimensions384H (including handle) x 212W x 312D mm
Power150 Watts
Voltage115Vac or 230Vac 50/60Hz
Weight10.2kg
NoteEthernet – supporting software and USB Host
Note* In ambient of 20°C: Min. Temperature is 55°C Below Ambient, Absolute Minimum -45°C

Documentos

  • Hyperion-4936

    Hyperion 4936

    Need advice on which model? Dry Block Selection Guide

  • Pegasus-4853

    Pegasus 4853

    Need advice on which model? Dry Block Selection Guide

  • Model-787

    787 High Rugged Dry Block Calibrator

    The Model 787 calibrator redefines industry standards by blending industry leading performance and speed of operation within a robust design tailored…

  • Model-983

    Small Hot Plate Model 983

    The Isotech Small Hotplate is a lightweight portable calibration system purpose designed for surface mounted sensors. The flat surface plate is made…

  • Semi-Standard-Thermocouples

    Semi Standard Thermocouples

    These thermocouples are suitable for use as references in Isotech Dry Blocks and for use with temperature indicators. Details of our laboratory grade…

  • Model-944

    Model 944

    The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from…

  • Quick-Cal-High

    Quick Cal High

    Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary.

  • Europa-4520

    Europa 4520

    Need advice on which model? Dry Block Selection Guide

  • milliK

    milliK Precision Thermometer

    The milliK Precision Thermometer from Isotech sets a new standard for the high accuracy measurement and calibration of Platinum Resistance…

  • Semi-Standard-PRTs

    Semi Standard PRTS

    Isotech Semi-Standard Platinum Resistance Thermometers are designed for applications requiring high accuracy, good long-term stability and greater…