Phosphoric acid is used in a wide range of industrial applications, including the manufacture of:

Phosphoric acid (H₃PO₄) is a key industrial chemical with a wide range of applications. While it is most commonly associated with phosphate fertilizer production, its mildly acidic and non-toxic properties also make it valuable in the food, beverage, pharmaceutical, and cosmetics industries.
The most prevalent method for producing phosphoric acid is the wet process, in which phosphate rock reacts with sulfuric acid (H₂SO₄) to yield phosphoric acid (H₃PO₄) and gypsum as a byproduct.
Phosphoric acid concentration is typically expressed as phosphoric anhydride (% P₂O₅) rather than as H₃PO₄. The two primary grades are:

The wet process involves three primary steps: reaction, filtration, and concentration.
Reaction:
Phosphate rock is first ground and fed into a reactor, where it reacts with sulfuric acid. This step is known as acidulation. During this reaction, tricalcium phosphate from the rock is converted into phosphoric acid and calcium sulfate (CaSO₄) — commonly known as gypsum.
Maintaining sulfuric acid concentration between 93–98% is critical for optimal process performance. It ensures effective dissolution of phosphate rock, promotes proper formation of gypsum crystals for efficient filtration, and minimizes the water load that must be removed during acid concentration.

The Vaisala Polaris™ PR53GP Process Refractometer enables in-line monitoring of acid concentrations throughout the wet process, eliminating the need for manual sampling and titration. There are two key locations for inlet refractometer installation:


Vaisala Polaris PR53GC and PR53GP refractometers are built for demanding industrial environments. The PR53GC is ideal for small pipelines and bypass lines, while the PR53GP offers flexible installation in a wide range of pipe sizes using standard flanges.
The refractometer measurement output can be configured in the preferred unit—% sulfuric acid, % phosphoric acid, % P₂O₅, or refractive index.
Features:

para mapeamento e monitoramento de temperatura exigentes

para monitoramento de amplas faixas de temperaturas

para mapeamento e monitoramento de temperatura exigentes

para monitoramento de amplas faixas de temperaturas

Para ambientes exigentes com controle de temperatura

O sistema de monitoramento viewLinc Vaisala acompanha as condições ambientais usando os dispositivos sem fio VaiNet, da Vaisala, que usam a…

Um dos requisitos mais importantes para reduzir os custos de refrigeração é, em primeiro lugar, medir as condições corretamente. As primeiras…

O dióxido de carbono e outros gases compostos por dois ou mais átomos diferentes têm uma forma característica e exclusiva de absorver a radiação…

Outra abordagem para prevenir explosões é instalar equipamentos elétricos dentro de compartimentos "à prova de explosão". Esses compartimentos podem…
Um especialista responde com a solução, o instrumento e o serviço adequados.
Produtos para cotar
Ainda não há produtos. É possível escrever mesmo assim: um especialista responde.