Uma unidade da AKRIBIS One

Drago-4934

Drago 4934

Need advice on which model? Dry Block Selection Guide

Solicitar cotaçãoBaixar ficha técnica

Drago 4934

Features

  • Multi Function: Six Modes including Dry Block and Liquid Bath
  • 65mm Volume: Ideal Liquid Bath
  • Calibrate entire measurement loop - using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system
Drago 4934

Description

The Hyperion and Drago have large calibration volumes, 65mm x 160mm deep, which makes them ideal to use as portable liquid baths. Stirred liquid baths are suitable for temperature sensors of all types, sizes and shapes. Liquid Baths can provide smaller calibration uncertainties than dry blocks and when used with suitable reference thermometers, accuracies of up to 0.005°C can be achieved.

These models are part of the award winning Isocal-6 family and with a reference probe can be used with different accessories for Dry Block, Infrared, Surface Calibration and even with ITS-90 Fixed Point Cells for uncertainties to 0.001°C. In Dry Block Mode, the large 65mm diameter block allows for the calibration of either larger probes or for calibrating many sensors simultaneously.

As a Liquid bath the sensors can be placed directly into the stirred liquid thus avoiding the need for specially drilled blocks. If the liquid is directly in the block then the controller only model, or Basic (B) model, can be selected. However, instead of putting liquids directly in the block liquid containers can be used to facilitate rapid change of fluids. For greater accuracy, or when using a liquid container, Dry Block Insert, Blackbody Target or the Surface Sensor Kit a separate reference thermometer should be used to compensate for the varying offset between the controller and the accessory temperature.

Drago 4934

An ideal arrangement would be to include the handheld Isotech TTI-10 or the bench top Isotech milliK Precision Thermometer and Model 935-14-16 Semi Standard Platinum Resistance Thermometer. Alternatively the SITE or ADVANCED model can be selected; the SITE includes a temperature indicator for a reference probe. The ADVANCED also includes inputs for test thermometers, automatic temperature cycling, logging and additional sophisticated features.

All models include I-Cal Easy LOG software and the ADVANCED models additionally include software to manage logged data and configure the unit, more details.

Drago 4934

Specifications

Temperature Range*30°C to 250°C

ADVANCED Range

Stability: Dry Block/ Liquid Bath±0.005°C to ±0.030°C
Display Resolution0.001°C over whole range
Input Channel Accuracy: ThermocoupleE, J, K, N: ±0.2°C @ 660°C R: ±0.6°C S: ±0.7°C @ 660°C T: ±0.2°C @ 150°C
CJC Accuracy±0.35°C
Input Channel Accuracy: RTD±0.10°C across range

BASIC/ SITE Range

Stability±0.03°C
Display Resolution0.01°C from -19.99 to 99.99°C then 0.1°C: 0.01°C Over PC Interface

COMMON Specifications

StabilityBlackbody ±0.3°C Surface Sensor ±0.5°C ITS-90 Cells ±0.0005°C
Display Resolution 30.15°C
Uniformity – Radial, Liquid Bath Mode<0.007°C
Uniformity – Axial, Liquid Bath Mode (40mm)<0.013°C
Uniformity – Radial, Dry Block Mode (Between Wells)<0.008°C
Uniformity – Axial, Dry Block Mode (40mm)<0.040°C
Heating Time30°C to 250°C: 40 mins
Cooling Time250°C to 100°C: 80 mins
Insert Size65 x 160mm
Insert TypesStandard 8 x 8mm + 2 x 4.5mm, Undrilled or Custom Drilled
Power115 or 230Vac 50/60Hz 1000 Watts
Dimensions384H (including handle) x 212W x 312D mm
Weight8kg

Documentos

  • Model-786

    786 Low Rugged Dry Block Calibrator

    Operate confidently in cold environments, even as low as -29°C. The ruggedly designed Model 786 takes laboratory level performance into the harshest…

  • TTI-22

    TTI-22

    Quite simply the Isotech TTI-22 High Accuracy Thermometer sets new standards in the price to performance ratio for industrial and secondary…

  • Gemini-4857

    Gemini 4857

    Need advice on which model? Dry Block Selection Guide

  • Calisto-4953

    Calisto 4953

    Need advice on which model? Dry Block Selection Guide

  • milliK

    milliK Precision Thermometer

    The milliK Precision Thermometer from Isotech sets a new standard for the high accuracy measurement and calibration of Platinum Resistance…

  • Pegasus-T

    PEGASUS-T

    A New Solution…t o Calibrate Short Sensors at High Temperatures