Uma unidade da AKRIBIS One

Model-787

787 High Rugged Dry Block Calibrator

The Model 787 calibrator redefines industry standards by blending industry leading performance and speed of operation within a robust design tailored for extreme conditions. The maximum operating temperature is 660°C allowing wide range of senor types to be calibrated to high temperatures.

Solicitar cotaçãoBaixar ficha técnica

787 High Rugged Dry Block Calibrator

Features

  • Fast, reliable, and accurate
  • Rugged, IP56, designed for use in harsh environments
  • High temperature operation to +660°C
787 High Rugged Dry Block Calibrator

Description

Like its counterpart, the low-temperature Model 786, this unit was initially crafted for the rigorous demands of the US Navy, it conforms to stringent military standards, undergoing bench, bounce, and altitude testing. Encased in a high-impact resistance shell, its removable lid conveniently houses all the essential accessories. Other calibrators lack
the protection offered, for terrain, transit and storage the Model 787 is unrivalled.

Beyond its robust design, Model 787 is unparalleled in protection and functionality, offering unique reference channel input options, datalogging, and other advanced features.

787 High Rugged Dry Block Calibrator

Specifications

Temperature Range*35°C to 660°C

ADVANCED Range

Stability±0.03°C
Display Resolution0.01°C over whole range
Indicator Units°C, °F, K
InterfaceEthernet, USB Host
Accuracy: RTD Input Channel±0.05°C ±0.005% RDG
Accuracy: Thermocouple Input ChannelE,J,K,N: ±0.2°C @ 660°C R: ±0.6°C S: ±0.7°C @ 660°C T ±0.2°C @ 150°C
CJC Accuracy±0.35°C

BASIC / SITE Range

Stability±0.03°C to ±0.05°C
Display Resolution0.01°C from -40.00°C to 99.99 0.1°C: 0.01°C over PC Interface
Indicator Units°C, °F, K
InterfaceSerial

COMMON Specifications

Display Accuracy±1°C (500°C) ±2°C (650°C)
Radial Uniformity<0.08°C
Axial Uniformity<0.5°C
Heating Time35°C to 660°C in 30 minutes
Cooling Time660°C to 100°C in 90 minutes
Ingress ProtectionIP56
Storage Temperature-30°C to +71°C
Humidity0 to 90% (non-condensing)
Insert Dimensions25.4mm Diameter x 152mm Deep
Insert Pockets4.50mm, 4.50mm, 6.50mm, 8.00mm, all 148mm deep, M4 tapped hole for supplied extractor tool.
Power110 or 230 Vac, 50/60Hz, 800 Watts
DimensionsHeight 350mm Width 400mm Depth 275mm
Weight (nominal)18kg

Documentos

  • Hyperion-4936

    Hyperion 4936

    Need advice on which model? Dry Block Selection Guide

  • Venus-4951

    Venus 4951

    Need advice on which model? Dry Block Selection Guide

  • Calisto-4953

    Calisto 4953

    Need advice on which model? Dry Block Selection Guide

  • microK2

    microK² Precision Thermometry Bridge

    The microK² builds on the success of the original microK models that were quickly adopted by leading National Metrology Institutes and commercial…

  • Quick-Cal-High

    Quick Cal High

    Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary.