IFC200
USB Interface Cable Package for Standard Series Data Loggers.
Nota técnica
Stereo cables have black or colored plastic insulating rings that separate a stereo cable jack into three separate segments, called the tip, ring, and sleeve.
These three segments are then attached to three wires that are electrically separated with insulation, allowing each channel to send its own signal. Through flexing of the cable over time, the insulating material can split or separate and expose the bare wire of the three channels. This exposure can result in crosstalk, which will interrupt the communication between the IFC200 and data loggers.

It is also possible that the metal of the wire has separated from the jack itself, or separated somewhere inside of the length of cable. This would cause complete communication loss along a single segment.
A multimeter set to measure resistance in Ohms (Ω) can be used to test if either of these issues have occurred. To test for continuity and crosstalk, connect the test leads of the multimeter to each end of the stereo cable on the identical opposing segment.
When testing each segment, there should be a trivial amount of resistance measured from opposing tips, rings, and sleeves respectively. However, there should be no measured resistance between tip-to-ring, tip-to-sleeve, or ring-to-sleeve. If there is any measured resistance between these segments, or if there is no measured resistance between one of the three opposing segments of the cable, then it would be advisable to replace the stereo cable entirely.
When replacing the stereo cable, it’s important to make sure the replacement jack is identical to the original, in that it has three metal segments separated by two insulating rings.

USB Interface Cable Package for Standard Series Data Loggers.

2 position, pluggable terminal block for use with MadgeTech data loggers.

3 position pluggable terminal block for use with MadgeTech data loggers.

4 position pluggable terminal block for use with MadgeTech data loggers.

The EggTemp-RH is an egg-shaped temperature and humidity data logger. Includes ISO17025 accredited calibration certificate.

The EggTemp is an egg-shaped temperature data logger. Includes ISO17025 accredited calibration certificate.

La Punto de Rocío y Temperatura DMP5 Vaisala DRYCAP® está diseñada para la medición de humedad en línea en aplicaciones de secado industrial con…

El Dr. Lauri Reuter es una experta en el futuro de los alimentos y la persona a quien preguntar si alguna vez te has preguntado qué vamos a comer en…

Las empresas industriales continúan tomando medidas para minimizar sus emisiones de carbono. Muchos están reduciendo el uso de combustibles fósiles y…

En el proceso de caustificación, los químicos pasivos se convierten en químicos de cocina activos para producir licor blanco. Se utiliza en el…
Un especialista responde con la solución, el instrumento y el servicio que corresponden.
Productos para cotizar
Todavía no hay productos. Se puede escribir igual: un especialista responde.