IFC200
USB Interface Cable Package for Standard Series Data Loggers.
Nota técnica
Stereo cables have black or colored plastic insulating rings that separate a stereo cable jack into three separate segments, called the tip, ring, and sleeve.
These three segments are then attached to three wires that are electrically separated with insulation, allowing each channel to send its own signal. Through flexing of the cable over time, the insulating material can split or separate and expose the bare wire of the three channels. This exposure can result in crosstalk, which will interrupt the communication between the IFC200 and data loggers.

It is also possible that the metal of the wire has separated from the jack itself, or separated somewhere inside of the length of cable. This would cause complete communication loss along a single segment.
A multimeter set to measure resistance in Ohms (Ω) can be used to test if either of these issues have occurred. To test for continuity and crosstalk, connect the test leads of the multimeter to each end of the stereo cable on the identical opposing segment.
When testing each segment, there should be a trivial amount of resistance measured from opposing tips, rings, and sleeves respectively. However, there should be no measured resistance between tip-to-ring, tip-to-sleeve, or ring-to-sleeve. If there is any measured resistance between these segments, or if there is no measured resistance between one of the three opposing segments of the cable, then it would be advisable to replace the stereo cable entirely.
When replacing the stereo cable, it’s important to make sure the replacement jack is identical to the original, in that it has three metal segments separated by two insulating rings.

USB Interface Cable Package for Standard Series Data Loggers.

2 position, pluggable terminal block for use with MadgeTech data loggers.

3 position pluggable terminal block for use with MadgeTech data loggers.

4 position pluggable terminal block for use with MadgeTech data loggers.

The EggTemp-RH is an egg-shaped temperature and humidity data logger. Includes ISO17025 accredited calibration certificate.

The EggTemp is an egg-shaped temperature data logger. Includes ISO17025 accredited calibration certificate.

A sonda de temperatura e ponto de orvalho DMP5 Vaisala DRYCAP® foi desenvolvida para medição de umidade em linha em aplicações de secagem industrial…

Lauri Reuter é um especialista no futuro da alimentação e a pessoa certa para perguntar se você já se perguntou o que comeremos no futuro e como toda…

As empresas industriais continuam a tomar medidas para minimizar as suas emissões de carbono. Muitos estão a reduzir a utilização de combustíveis…

No processo de caustificação, os produtos químicos passivos são convertidos em produtos químicos ativos para cozinhar para produzir licor branco…
Um especialista responde com a solução, o instrumento e o serviço adequados.
Produtos para cotar
Ainda não há produtos. É possível escrever mesmo assim: um especialista responde.