HiTemp140-FP-12
HiTemp140-FP (HiTemp140-FP-12)
The HiTemp140-FP is a high temperature data logger with a flexible RTD probe. Includes ISO17025 accredited calibration certificate.
Solicitar cotizaciónDescargar ficha técnica
HiTemp140-FP-12
The HiTemp140-FP is a high temperature data logger with a flexible RTD probe. Includes ISO17025 accredited calibration certificate.
Solicitar cotizaciónDescargar ficha técnica
The HiTemp140-FP is a high temperature data logger built for use in harsh environments. The body of the HiTemp140-FP can withstand temperatures ranging from -40 °C to +140 °C (-40 °F to +284 °F), but can extend to higher temperatures when used with MadgeTech’s thermal barrier options.
The HiTemp140-FP is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
| Memory | 32,356 readings |
|---|---|
| Reading Rate | 1 reading every 0.25 seconds up to 1 reading every 24 hours |
| Baud Rate | 125,000 |
| Battery Life | 2 years typical (1 minute reading rate); Fast reading intervals and extreme temperatures will shorten the battery life substantially; User Replaceable Battery |
| Material | Body: 316 Stainless Steel, Radel; Probe: PFA Insulated Cable with Stainless Steel Tip |
| Dimensions | Body: 2.95 in x 0.97 in x 0.97 in (75 mm x 24.6 mm x 24.6 mm); Probes: HiTemp140-FPST-6: 6 in x 0.13 in (152.5 mm x 3.2 mm); HiTemp140-FPST-12: 12 in x 0.13 in (304.8 mm x 3.2 mm); HiTemp140-FPST-36: 36 in x 0.13 in (914 mm x 3.2 mm); HiTemp140-FPST-72: 72 in x 0.13 in (1829 mm x 3.2 mm) |
| Key Ring End Cap | Key ring replaces standard bottom; Thru-hole: 0.150" |
| IP Rating | IP68 |
| Submersible | Yes |
| Operating Environment | -40 °C to +140 °C (-40 °F to +284 °F) Body of Logger Cannot Exceed 140 °C; 0 %RH to 100 %RH, 0 PSIA to 100 PSIA; With Thermal Shield: -200 °C to +250 °C (-328 °F to +482 °F) |
| Required Interface Package | IFC400 or IFC406 |
| Approvals | CE |
| Weight | 0.1875 LBS |
| Temperature Sensor | Flexible RTD Probe |
|---|---|
| Temperature Resolution | 0.01 °C (0.018 °F) |
| Temperature Calibrated Accuracy | ±0.1 °C from +20 °C to +140 °C; ±0.3 °C from -20 °C to +19.99 °C; ±0.4 °C from -40 °C to -20.01 °C |
| Probe Temperature Range | -200 °C to +260 °C (-328 °F to +500 °F); (Body of Logger Cannot Exceed 140 °C) |
Elija modelo, sondas y accesorios. Las combinaciones incompatibles se bloquean solas; el resto de las reglas se verifica al agregar el equipo a la cotización.
Cargando las opciones…
Se puede pegar un código y la configuración se arma sola.
Se piden por separado: no hace falta configurar el equipo.



Versatile stand for use with the HiTemp140, PRTemp140, PR140, Temp1000 and RHTemp1000 series of data loggers.




One set of replacement o-rings for the HiTemp140, RHTemp1000, PR140, PRTemp140 PR1000.




Magnetic Holder for use with the PR140, PRTemp140, HiTemp140, Temp1000, and RHTemp1000 Series Data Loggers.

Surface temperature probe attachment designed to be used with the MadgeTech HiTemp140-FP and LyoTemp Data Loggers.

Versatile mount or stand for use with the HiTemp140 series of data loggers.

Extreme Temperature Thermal Barrier for HiTemp140 Data Loggers.
Instrumentos para cotizar
Todavía no hay instrumentos. Se puede escribir igual: un especialista responde.