Una unidad de AKRIBIS One

Temp1000Ex-2-KR

Temp1000Ex (Temp1000Ex-2-KR)

The Temp1000Ex temperature data logger carries hazardous location certification (ATEX, IECEx). Includes ISO 17025 accredited calibration certificate.

Solicitar cotizaciónDescargar ficha técnica

Temp1000Ex (Temp1000Ex-2-KR)

Key Features

  • Compact Size
  • ATEX Approved
  • Available in a Variety of Probe Lengths
Temp1000Ex (Temp1000Ex-2-KR)

Description

The Temp1000Ex is a compact, temperature data logger that carries hazardous location certification (ATEX, IECEx).

This one of a kind data logger is certified intrinsically safe for the following:

  • Electrical Protection Concepts: ISO/IEC: 60079-11 Ex ia – Ex ic, Intrinsic Safety Zones 0-2
  • Equipment Protection Level: Ga – Gc, Zones 0-2
  • Gas Group: IIC
  • Temperature Class: T4

The Temp1000Ex measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C (0 °C to +55 °C) and ±0.9 °F (+32 °F to +131 °F). The Temp1000Ex can store up to 32,767 time and date stamped readings, and is available with either a flush bottom or key ring end cap.

The Temp1000Ex is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

General

Memory65,536 Readings
Reading Rate1 reading every second up to 1 reading every 24 hours
Battery Life2 years typical at 15 minute reading rate
Material316 Stainless Steel/Radel
Dimensions2.66 in x .97 in dia. (67.6 mm x 24.6 mm dia.)
Key Ring End CapKey ring replaces standard bottom; Thru-hole: 0.150"
IP RatingIP68
Operating Environment-40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 100 %RH (case properly sealed)
Required Interface PackageIFC400 or IFC406
ApprovalsCE; ATEX Certificate #: 19ATEX0126; IECEx Certificate #: BAS 19.0109

Temperature

Temperature SensorResistance Temperature Detector (RTD)
Temperature Range-40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution0.01 °C (0.018 °F)
Temperature Calibrated Accuracy±0.5 °C (0 °C to +55 °C), ±0.9 °F (32 °F to 131 °F)

Configurar el equipo

Elija modelo, sondas y accesorios. Las combinaciones incompatibles se bloquean solas; el resto de las reglas se verifica al agregar el equipo a la cotización.

Documentos

  • IFC406

    IFC406

    IFC406 Multiplexer Data Logger Interface.

  • MagMount-1

    MagMount-1

    Magnetic Holder for use with the PR140, PRTemp140, HiTemp140, Temp1000, and RHTemp1000 Series Data Loggers.

  • IFC400

    IFC400

    Interface Cable Package for the HiTemp140 and PR140 Data Loggers.

  • DLS100

    DLS100

    Versatile stand for use with the HiTemp140, PRTemp140, PR140, Temp1000 and RHTemp1000 series of data loggers.

Escribir por WhatsApp