Una unidad de AKRIBIS One

Model-988

Blackbody Source Model 988

Improves Accuracy of Fever Detection Systems; Can be used either horizontally or vertically.; Check Non-Contact Thermometers; Features a high emissivity ridged plate that is 70 mm diameter

Solicitar cotizaciónDescargar ficha técnica

Blackbody Source Model 988

Features

  • Improves Accuracy of Fever Detection Systems
  • Can be used either horizontally or vertically.
  • Check Non-Contact Thermometers
  • Features a high emissivity ridged plate that is 70 mm diameter
Blackbody Source Model 988

Descripton

Legacy Product – Replaced with the upgradedModel 989

First introduced to assist in relation to the SARS outbreak during the early 2000s the Model 988 is now helping in relation to coronavirus. It can be used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications. It can also be used to check non-contact clinical thermometers.

This blackbody meets the demand for a simple, cost effective but high accuracy calibrator for the calibration of thermal imagers and infrared thermometers used at temperatures around human body temperature.

A 70 mm diameter ridged plate is heated or cooled with an internal solid state thermoelectric heat pump. The temperature of the plate can be set from 20°C to 45°C to a resolution of 0.1°C.

The standard version has a 210mm long tube mainly used with thermal imagers. A second version has a 40mm tube more suited for checking medical thermometers.

Blackbody Source Model 988

Specifications

Model988
Temperature Range20°C to 45°C
Resolution±0.1°C
Target Size70mm Diameter
Sighting Tube Diameter54mm Diameter
Emissivity0.97 ± 0.02
Combined Accuracy / Stability±0.2°C (±0.3°F)
Power60 Watts
Voltage12 Vdc
DimensionsHeight 230mm Width 225mm Depth 115mm
Weight4kg

Optional PC Interface

AccessoriesSwitch Mode Power Supply Supplied as Standard 100-240 VAC
How to orderModel 988

Documentos

  • Model-991

    991 Tympanic Thermometer Checker

    Addressing Calibration Challenges Traditional calibration methods using stirred water baths are cumbersome, expensive, and not easily portable…

  • Cyclops-878

    Cyclops Model 878

    The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for…

  • Gemini-R-976

    Gemini R Model 976

    The Gemini R 550 Portable Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to…

  • QuickCal-Blackbody

    QuickCal Blackbody

    When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared…

  • Blackbody-ITS-90-Fixed-Points

    Blackbody ITS-90 Fixed Points

    Primary Standard cells fit into the Medusa and Oberon, covering from Indium to Copper Points. These cylindrical cells are 42mm diameter and have a…

  • Pegasus-R-970

    Pegasus R Model 970

    The Pegasus R is a compact furnace for calibrating radiation pyrometers.

  • Hyperion-R-982

    Hyperion R Portable Blackbody 982

    The Hyperion R Portable Blackbody Calibration Source allows for calibration of non-contact infrared thermometers over the temperature range -20°C to…

  • Model-989

    Blackbody Source Model 989

    Isotech first introduced the Model 988 to assist in relation to the SARS outbreak during the early 2000s. Used to increase the accuracy of thermal…