991 Tympanic Thermometer Checker
Addressing Calibration Challenges Traditional calibration methods using stirred water baths are cumbersome, expensive, and not easily portable…
Model-988
Improves Accuracy of Fever Detection Systems; Can be used either horizontally or vertically.; Check Non-Contact Thermometers; Features a high emissivity ridged plate that is 70 mm diameter
Solicitar cotaçãoBaixar ficha técnica

Legacy Product – Replaced with the upgradedModel 989
First introduced to assist in relation to the SARS outbreak during the early 2000s the Model 988 is now helping in relation to coronavirus. It can be used to increase the accuracy of thermal imagers being used to measure human skin temperature in temperature screening of applications. It can also be used to check non-contact clinical thermometers.
This blackbody meets the demand for a simple, cost effective but high accuracy calibrator for the calibration of thermal imagers and infrared thermometers used at temperatures around human body temperature.
A 70 mm diameter ridged plate is heated or cooled with an internal solid state thermoelectric heat pump. The temperature of the plate can be set from 20°C to 45°C to a resolution of 0.1°C.
The standard version has a 210mm long tube mainly used with thermal imagers. A second version has a 40mm tube more suited for checking medical thermometers.

| Model | 988 |
|---|---|
| Temperature Range | 20°C to 45°C |
| Resolution | ±0.1°C |
| Target Size | 70mm Diameter |
| Sighting Tube Diameter | 54mm Diameter |
| Emissivity | 0.97 ± 0.02 |
| Combined Accuracy / Stability | ±0.2°C (±0.3°F) |
| Power | 60 Watts |
| Voltage | 12 Vdc |
| Dimensions | Height 230mm Width 225mm Depth 115mm |
| Weight | 4kg |
| Accessories | Switch Mode Power Supply Supplied as Standard 100-240 VAC |
|---|---|
| How to order | Model 988 |

Addressing Calibration Challenges Traditional calibration methods using stirred water baths are cumbersome, expensive, and not easily portable…

The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for…

The Gemini R 550 Portable Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to…

When the high accuracy of the Gemini R is not necessary this product offers a cost effective solution for the calibration and testing of infrared…

Primary Standard cells fit into the Medusa and Oberon, covering from Indium to Copper Points. These cylindrical cells are 42mm diameter and have a…


The Hyperion R Portable Blackbody Calibration Source allows for calibration of non-contact infrared thermometers over the temperature range -20°C to…