991 Tympanic Thermometer Checker
Addressing Calibration Challenges Traditional calibration methods using stirred water baths are cumbersome, expensive, and not easily portable…
Gemini-R-976
The Gemini R 550 Portable Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C. It is suitable for use as a primary radiation source for infrared thermometers.
Solicitar cotaçãoBaixar ficha técnica
Laboratory performance and low uncertainty calibrations are ensured by the combination by high emissivity and excellent temperature uniformity.
The digital temperature controller allows the block temperature to bet set to any value from 30°C to 550°C. Traceability of the radiance temperature is established by a separate, built-in temperature indicator and included platinum resistance thermometer.
A three point traceable calibration certificate is included. UKAS calibration of the resistance thermometer is available, as is radiometric calibration.
Uniformity of the block is ensured by using distributed heating technology.
For the smallest of uncertainties the Gemini R may be used with Isotech ITS-90 Fixed Point Cells, Gallium 29.7646°C, Indium 156.5985°C, Tin 231.928°C and Zinc 419.527°C. The cells are provided with a certificate of metal purity.

| Model | 976 |
|---|---|
| Temperature Range | 30°C to 550.0°C |
| Emissivity | Greater than 0.995 |
| Stability | ±0.1°C |
| Display Resolution | 0.01°C to 99.99; 0.1°C from 100 to 550 |
| Heating Time | 45 minutes |
| Aperture Diameter | 65mm |
| Cavity Depth | 160mm |
| PC Interface | Included |
| Power | 1000 Watts typical |
| Voltage | 100-130 or 208-240 Vac 50/60Hz |
| Dimensions | Height 310mm Width 265mm Depth 200mm |
| Weight | 10kg |
| Options | Fixed Point Cell: Gallium Hockey Puck Cell -431-03-00 Indium Hockey Puck Cell -976-05-00A Tin Hockey Puck Cell -976-05-00B Zinc Hockey Puck Cell -976-05-00C Orfice Plates 10, 20, 30, 40, 50mm -976-01-05 (Restricts Cavity Aperture) Carrying Case -931-22-64 |
| How to order | Model 976 Gemini R: State Supply Voltage. Please state any special calibration requirements. |

Addressing Calibration Challenges Traditional calibration methods using stirred water baths are cumbersome, expensive, and not easily portable…

Improves Accuracy of Fever Detection Systems; Can be used either horizontally or vertically.; Check Non-Contact Thermometers; Features a high…

The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of…

The higher temperature Isotech Blackbody Fixed Point Cells consist of high purity metals within a graphite body. Graphite reacts with air to form…

The Hyperion R Portable Blackbody Calibration Source allows for calibration of non-contact infrared thermometers over the temperature range -20°C to…

The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for…

The Medusa R Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C.

Primary Standard cells fit into the Medusa and Oberon, covering from Indium to Copper Points. These cylindrical cells are 42mm diameter and have a…
Instrumentos para cotar
Ainda não há instrumentos. É possível escrever mesmo assim: um especialista responde.