Uma unidade da AKRIBIS One

Quick-Cal-Low

Quick Cal Low

Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary.

Solicitar cotaçãoBaixar ficha técnica

Quick Cal Low

Features

  • Fast
  • Compact
  • Value with ease of use
Quick Cal Low

Description

The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ideal for the medical, sterilisation and food industries.

The High Temperature Quick Cal covers the temperature range from 30°C to 350°C.

Both have interchangeable inserts, so you don’t have to buy another calibrator each time you find a new diameter sensor to calibrate. The Low Temperature Quick Cal is particularly exciting since it can work from a small 12 volt battery, making it truly portable, alternatively a mains supply is available with 100V – 240V, 50/60Hz input.

The Low Temperature Quick Cal comes complete with two inserts, one blank and one drilled 6.8mm diameter 120mm deep. Alternatively we can provide pre-drilled inserts to suit your needs. Each calibration well is 13mm diameter and 120mm deep.

The High Temperature Quick Cal has a single larger well and interchangeable inserts, 25mm in diameter by 120mm deep. Blank and other special drillings are available to order. The High Temperature Quick Cal is supplied 100-130 or 200-250V AC, 50/60Hz.

The manual which accompanies the Quick Cal contains helpful advice on how to get the best from your calibrator.

Accessories for the above include a carry case, alternative inserts and a rechargeable battery for the Low Temperature Quick Cal.

Quick Cal Low

Specifications

ParameterModelLow Temperature Quick-Cal
Temperature Range-12°C to + 140°C. In an ambient of 20°C the Quick-Cal will achieve lower temperature if used in a lower ambient temperature.
Set Point Resolution0.1°C over range
Accuracy±0.1°C to ±0.4°C using comparison techniques. ±0.4°C against display temperature with a single probe in the 6.8mm drilled sleeve.
Stability±0.05°C±0.05°C
Time to set point9 minutes from 0°C to 100°C
Additional time for best stabilityTypically 5 minutes
Calibration VolumeTwo 13mm diameter pockets 120mm deep. Supplied with two sleeves, one blank and one drilled 6.8mm diameter, 120mm deep.
Voltage15Vdc or 100-240V, switch mode power supply (50/60hz)
Power70W350W
DimensionsHeight 65mm, Width 152mm, Depth 175mm, Weight 1.5kg

Documentos

  • Model-944

    Model 944

    The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from…

  • Model-786

    786 Low Rugged Dry Block Calibrator

    Operate confidently in cold environments, even as low as -29°C. The ruggedly designed Model 786 takes laboratory level performance into the harshest…

  • Quick-Cal-High

    Quick Cal High

    Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary.

  • Fast-Cal-Medium

    Fast-Cal Medium

    Need advice on which model? Dry Block Selection Guide

  • Model-983

    Small Hot Plate Model 983

    The Isotech Small Hotplate is a lightweight portable calibration system purpose designed for surface mounted sensors. The flat surface plate is made…

  • Medusa-511

    Medusa 511

    Need advice on which model? Dry Block Selection Guide

  • Model-526

    Model 526 Low Temperature Calibration Source