Uma unidade da AKRIBIS One

Model-944

Model 944

The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from the surface of the hot-plate causes a localised cold spot to be created which means that the temperature indicated by the hot plate is not necessarily the temperature at the point of measurement.

Solicitar cotaçãoBaixar ficha técnica

Model 944

Features

  • Indicates True Surface Temperature
  • 30°C to 350°C
  • Resolution 0.1°C
Model 944

Description

An ideal system would not disturb the heat-flux from the hot-plate.

During 1993 such a system was described (ref. “Progress in Contact Thermometry” 1993 B. D. Foulis) and Isotech have the inventor’s permission to make and market the device World-wide.

Principal of Operation

A fine wire type N thermocouple is used as the surface temperature sensor, a second junction 2 to 3mm along the thermocouple, senses the temperature difference due to heat flux along the sensor.

A heater heats the thermocouple stem until the temperature gradient is zero, thus creating a measurement without stem conduction, or disturbance of the hot-plate’s surface.

The 944 can be used with the Isotech Small Hot Plate model 983. A traceable calibration certificate is available to order.

Model 944

Specifications

Model944 True Surface Temperature Measurement System
Temperature Range30°C to 350°C
Resolution of Display0.1°C or 0.1°F
Stability±0.1°C
Accuracy±2°C with TRACEABLE Certification ±5°C without Certification
Probe AssemblyProbe Diameter – 7.5mm Probe Length – 150mm Lead Length – 850mm
Power Supply100V – 120V, 50/60Hz or 200V – 240V, 50/60Hz
DimensionsHeight 90mm Width 153mm Depth 265mm (excluding plugs)
Weight4kg
How to orderModel 944 & Probe 935-14-81 Please state supply voltage required. Please state if Calibration is required.

Documentos

  • Quick-Cal-Low

    Quick Cal Low

    Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary.

  • Europa-4520

    Europa 4520

    Need advice on which model? Dry Block Selection Guide

  • Model-786

    786 Low Rugged Dry Block Calibrator

    Operate confidently in cold environments, even as low as -29°C. The ruggedly designed Model 786 takes laboratory level performance into the harshest…

  • TTI-22

    TTI-22

    Quite simply the Isotech TTI-22 High Accuracy Thermometer sets new standards in the price to performance ratio for industrial and secondary…

  • Model-836

    Miniature Fixed Resistor Model 836

    Isotech produces a miniature resistor with ultra-low temperature coefficient and ultra-high stability. This is achieved because the resistors are oil…

  • milliK

    milliK Precision Thermometer

    The milliK Precision Thermometer from Isotech sets a new standard for the high accuracy measurement and calibration of Platinum Resistance…

  • Semi-Standard-PRTs

    Semi Standard PRTS

    Isotech Semi-Standard Platinum Resistance Thermometers are designed for applications requiring high accuracy, good long-term stability and greater…

  • Venus-4951

    Venus 4951

    Need advice on which model? Dry Block Selection Guide

  • millisKanner

    millisKanner Channel Expander

    The millisKanner channel expander has eight input channels, and each can be configured individually for SPRT, PRT, Thermistor or Thermocouple input…

  • Jupiter-4852

    Jupiter 4852

    Need advice on which model? Dry Block Selection Guide