A unit of AKRIBIS One

Quick-Cal-Low

Quick Cal Low

Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary.

Request a quoteDownload the datasheet

Quick Cal Low

Features

  • Fast
  • Compact
  • Value with ease of use
Quick Cal Low

Description

The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ideal for the medical, sterilisation and food industries.

The High Temperature Quick Cal covers the temperature range from 30°C to 350°C.

Both have interchangeable inserts, so you don’t have to buy another calibrator each time you find a new diameter sensor to calibrate. The Low Temperature Quick Cal is particularly exciting since it can work from a small 12 volt battery, making it truly portable, alternatively a mains supply is available with 100V – 240V, 50/60Hz input.

The Low Temperature Quick Cal comes complete with two inserts, one blank and one drilled 6.8mm diameter 120mm deep. Alternatively we can provide pre-drilled inserts to suit your needs. Each calibration well is 13mm diameter and 120mm deep.

The High Temperature Quick Cal has a single larger well and interchangeable inserts, 25mm in diameter by 120mm deep. Blank and other special drillings are available to order. The High Temperature Quick Cal is supplied 100-130 or 200-250V AC, 50/60Hz.

The manual which accompanies the Quick Cal contains helpful advice on how to get the best from your calibrator.

Accessories for the above include a carry case, alternative inserts and a rechargeable battery for the Low Temperature Quick Cal.

Quick Cal Low

Specifications

ParameterModelLow Temperature Quick-Cal
Temperature Range-12°C to + 140°C. In an ambient of 20°C the Quick-Cal will achieve lower temperature if used in a lower ambient temperature.
Set Point Resolution0.1°C over range
Accuracy±0.1°C to ±0.4°C using comparison techniques. ±0.4°C against display temperature with a single probe in the 6.8mm drilled sleeve.
Stability±0.05°C±0.05°C
Time to set point9 minutes from 0°C to 100°C
Additional time for best stabilityTypically 5 minutes
Calibration VolumeTwo 13mm diameter pockets 120mm deep. Supplied with two sleeves, one blank and one drilled 6.8mm diameter, 120mm deep.
Voltage15Vdc or 100-240V, switch mode power supply (50/60hz)
Power70W350W
DimensionsHeight 65mm, Width 152mm, Depth 175mm, Weight 1.5kg

Documents

  • Model-944

    Model 944

    The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from…

  • Model-786

    786 Low Rugged Dry Block Calibrator

    Operate confidently in cold environments, even as low as -29°C. The ruggedly designed Model 786 takes laboratory level performance into the harshest…

  • Quick-Cal-High

    Quick Cal High

    Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary.