Small Hot Plate Model 983
The Isotech Small Hotplate is a lightweight portable calibration system purpose designed for surface mounted sensors. The flat surface plate is made…
Semi-Standard-PRTs
Isotech Semi-Standard Platinum Resistance Thermometers are designed for applications requiring high accuracy, good long-term stability and greater robustness than a traditional Standard Platinum Resistance Thermometer (SPRT). They are suitable for both laboratory and field use, including as working standards in dry blocks and liquid baths, or as high-accuracy sensors used with precision temperature readouts.
Solicitar cotaçãoBaixar ficha técnica

All models are metal sheathed, making them less fragile and more practical for routine calibration work than laboratory SPRTs, while still offering excellent measurement performance.
Each thermometer uses a handmade, coil-wound Pt100 platinum sensing element selected for high accuracy, low drift and long-term stability. The probes are available in a range of lengths, diameters and temperature ranges to suit different calibration applications.
Angled and 90° versions are also available for use with Isotech Portable Temperature Calibrators. These provide additional clearance where a unit under test has a terminal head or connection housing that would otherwise obstruct a straight reference thermometer. For best measurement performance, these probes should be calibrated as part of the portable calibrator system.
Isotech’s UKAS accredited laboratory can calibrate Semi-Standard PRTs to low uncertainties across their operating range. The calibration should be selected to suit the required temperature range, measurement uncertainty and application, and Isotech can advise on the most appropriate calibration service.

</tr

Typical Uncertainties with Optional Isotech UKAS Accredited Calibration, k = 2.
The above uncertainties do not include long-term drift.
Typical stability of a correctly used Semi-Standard PRT is 0.01°C/year at 0°C.
The actual uncertainty of an individual probe is determined at the time of calibration.

| Ro | 100Ω ± 0.05Ω |
|---|---|
| Alpha | 0.003850 ± 0.000005 |
| Standard | IEC 60751 |
| Stability | 0.010Ω/ year |
| Recommended Current | 1mA |
| Self Heating at 1mA | 0.004°C |
| Calibration | Optional UKAS Calibration at extra cost. See table for typical uncertainties. |
| Connection | 4 Wire |
| Max. Handle Temperature | 80°C |
| Model | Temperature Range | Sheath Diameter | Sheath Length | Sensing Length | Handle |
|---|---|---|---|---|---|
| 935-14-61 | −50°C to 250°C | 4 mm | 300 mm | 6 mm | 19 × 120 mm |
| 935-14-112 | −50°C to 250°C | 4 mm | 300 mm | 6 mm | No Handle |
| 935-14-98 | −50°C to 350°C | 4 mm | 300 mm | 8 mm | No handle |
| 935-14-116 | −100°C to 450°C | 6 mm | 350 mm | 25 mm | 19 × 120 mm |
| 935-14-98 | −50°C to 350°C | 4 mm | 300 mm | 8 mm | No handle |
| Model | Temperature Range | Sheath Diameter | Sheath Length | Sensing Length | Handle |
|---|---|---|---|---|---|
| 935-14-115 | −196°C to 100°C | 4 mm | 300 mm | 8 mm | Ø 17.5 mm |
| 935-14-13 | −196°C to 250°C | 6 mm | 350 mm | 25 mm | 25 × 115 mm |
| 935-14-113 | −100°C to 250°C | 6 mm | 350 mm | 25 mm | 19 × 120 mm |
| Model | Temperature Range | Sheath Diameter | Sheath Length | Sensing Length | Handle |
|---|---|---|---|---|---|
| 935-14-72 | −50°C to 670°C | 6 mm | 375 mm | 25 mm | No handle |
| Model | Temperature Range | Sheath Diameter | Sheath Length | Sensing Length | Handle |
|---|---|---|---|---|---|
| 935-14-95L | −200°C to 165°C | 6 mm | 480 mm | 25 mm | 25 × 115 mm |
| 935-14-95H | −80°C to 670°C | 6 mm | 480 mm | 25 mm | 19 × 120 mm |
Longer probes designed primarily for laboratory use. The low- and high-temperature models can be used as a complementary pair where coverage from −200°C to 660°C is required.
| Model | Temperature Range | Sheath Diameter | Sheath Length | Sensing Length | Handle |
|---|---|---|---|---|---|
| 935-14-82 | −50°C to 250°C | 4 mm | 165 mm | 6 mm | Angled |
| 935-14-85 | −50°C to 250°C | 6 mm | 385 mm | 25 mm | Angled |
| 935-14-75 | −50°C to 250°C | 4 mm | 213 mm | 6 mm | 90° |
| 935-14-79 | 0°C to 660°C | 6 mm | 199 mm | 25 mm | 90° |
| Temperature | 935-14-95L | 935-14-61 | 935-14-13 | 935-14-16 935-14-116 | 935-14-95H 935-14-72 |
|---|---|---|---|---|---|
| −196°C | 25 mK | N/A | 25 mK | N/A | N/A |
| −80°C | 20 mK | N/A | 20 mK | 25 mK | 25 mK |
| −50°C | 15 mK | 15 mK | 15 mK | 20 mK | 20 mK |
| 0°C | 10 mK | 10 mK | 10 mK | 15 mK | 15 mK |
| 50°C | 10 mK | 10 mK | 10 mK | 15 mK | 15 mK |
| 156°C | 10 mK | 10 mK | 10 mK | 20 mK | 20 mK |
| 232°C | N/A | 15 mK | 15 mK | 25 mK | 25 mK |
| 420°C | N/A | N/A | N/A | 40 mK | 40 mK |
| 550°C | N/A | N/A | N/A | N/A | 50 mK |
| 660°C | N/A | N/A | N/A | N/A | 50 mK |

The Isotech Small Hotplate is a lightweight portable calibration system purpose designed for surface mounted sensors. The flat surface plate is made…


The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from…

The milliK Precision Thermometer from Isotech sets a new standard for the high accuracy measurement and calibration of Platinum Resistance…




Instrumentos para cotar
Ainda não há instrumentos. É possível escrever mesmo assim: um especialista responde.