A unit of AKRIBIS One

Semi-Standard-PRTs

Semi Standard PRTS

Isotech Semi-Standard Platinum Resistance Thermometers are designed for applications requiring high accuracy, good long-term stability and greater robustness than a traditional Standard Platinum Resistance Thermometer (SPRT). They are suitable for both laboratory and field use, including as working standards in dry blocks and liquid baths, or as high-accuracy sensors used with precision temperature readouts.

Request a quoteDownload the datasheet

Semi Standard PRTS

Features

  • High accuracy from −200°C to 670°C
  • Working standards for dry blocks and liquid baths
  • Straight and angled models for laboratory and field use
Semi Standard PRTS

Description

All models are metal sheathed, making them less fragile and more practical for routine calibration work than laboratory SPRTs, while still offering excellent measurement performance.

Each thermometer uses a handmade, coil-wound Pt100 platinum sensing element selected for high accuracy, low drift and long-term stability. The probes are available in a range of lengths, diameters and temperature ranges to suit different calibration applications.

Angled and 90° versions are also available for use with Isotech Portable Temperature Calibrators. These provide additional clearance where a unit under test has a terminal head or connection housing that would otherwise obstruct a straight reference thermometer. For best measurement performance, these probes should be calibrated as part of the portable calibrator system.

Isotech’s UKAS accredited laboratory can calibrate Semi-Standard PRTs to low uncertainties across their operating range. The calibration should be selected to suit the required temperature range, measurement uncertainty and application, and Isotech can advise on the most appropriate calibration service.

Semi Standard PRTS

Model types

</tr

Semi Standard PRTS

Typical uncertainties with optional ukas calibration

Typical Uncertainties with Optional Isotech UKAS Accredited Calibration, k = 2.
The above uncertainties do not include long-term drift.
Typical stability of a correctly used Semi-Standard PRT is 0.01°C/year at 0°C.
The actual uncertainty of an individual probe is determined at the time of calibration.

Semi Standard PRTS

Specifications

Ro100Ω ± 0.05Ω
Alpha0.003850 ± 0.000005
StandardIEC 60751
Stability0.010Ω/ year
Recommended Current1mA
Self Heating at 1mA0.004°C
CalibrationOptional UKAS Calibration at extra cost. See table for typical uncertainties.
Connection4 Wire
Max. Handle Temperature80°C

General Purpose

ModelTemperature RangeSheath DiameterSheath LengthSensing LengthHandle
935-14-61−50°C to 250°C4 mm300 mm6 mm19 × 120 mm
935-14-112−50°C to 250°C4 mm300 mm6 mmNo Handle
935-14-98−50°C to 350°C4 mm300 mm8 mmNo handle
935-14-116−100°C to 450°C6 mm350 mm25 mm19 × 120 mm
935-14-98−50°C to 350°C4 mm300 mm8 mmNo handle

Low Temperature PRTs

ModelTemperature RangeSheath DiameterSheath LengthSensing LengthHandle
935-14-115−196°C to 100°C4 mm300 mm8 mmØ 17.5 mm
935-14-13−196°C to 250°C6 mm350 mm25 mm25 × 115 mm
935-14-113−100°C to 250°C6 mm350 mm25 mm19 × 120 mm

High Temperature PRTs

ModelTemperature RangeSheath DiameterSheath LengthSensing LengthHandle
935-14-72−50°C to 670°C6 mm375 mm25 mmNo handle

Laboratory Working Standards

ModelTemperature RangeSheath DiameterSheath LengthSensing LengthHandle
935-14-95L−200°C to 165°C6 mm480 mm25 mm25 × 115 mm
935-14-95H−80°C to 670°C6 mm480 mm25 mm19 × 120 mm

Longer probes designed primarily for laboratory use. The low- and high-temperature models can be used as a complementary pair where coverage from −200°C to 660°C is required.

Angled Probes

ModelTemperature RangeSheath DiameterSheath LengthSensing LengthHandle
935-14-82−50°C to 250°C4 mm165 mm6 mmAngled
935-14-85−50°C to 250°C6 mm385 mm25 mmAngled
935-14-75−50°C to 250°C4 mm213 mm6 mm90°
935-14-790°C to 660°C6 mm199 mm25 mm90°

Typical uncertainties with optional ukas calibration

Temperature935-14-95L935-14-61935-14-13935-14-16 935-14-116935-14-95H 935-14-72
−196°C25 mKN/A25 mKN/AN/A
−80°C20 mKN/A20 mK25 mK25 mK
−50°C15 mK15 mK15 mK20 mK20 mK
0°C10 mK10 mK10 mK15 mK15 mK
50°C10 mK10 mK10 mK15 mK15 mK
156°C10 mK10 mK10 mK20 mK20 mK
232°CN/A15 mK15 mK25 mK25 mK
420°CN/AN/AN/A40 mK40 mK
550°CN/AN/AN/AN/A50 mK
660°CN/AN/AN/AN/A50 mK

Documents

  • Model-983

    Small Hot Plate Model 983

    The Isotech Small Hotplate is a lightweight portable calibration system purpose designed for surface mounted sensors. The flat surface plate is made…

  • Gemini-4857

    Gemini 4857

    Need advice on which model? Dry Block Selection Guide

  • Model-944

    Model 944

    The fundamental problem with surface temperature measurement is that it is subject to large stem conduction errors, also because heat conducted from…

  • milliK

    milliK Precision Thermometer

    The milliK Precision Thermometer from Isotech sets a new standard for the high accuracy measurement and calibration of Platinum Resistance…

  • Fast-Cal-Medium

    Fast-Cal Medium

    Need advice on which model? Dry Block Selection Guide

  • Hyperion-4936

    Hyperion 4936

    Need advice on which model? Dry Block Selection Guide

  • Pegasus-4853

    Pegasus 4853

    Need advice on which model? Dry Block Selection Guide

  • Venus-4951

    Venus 4951

    Need advice on which model? Dry Block Selection Guide