Although its seems simple, candle production is a relatively complicated process. To make sure the candle is of a suitable quality, it is necessary to focus on the composition of the wax (materials mix) used to make it as well as the quality and type of the wick. The candle wick has a substantial impact on the candle while it is burning out, especially with regard to combustion products (particulates, soot). There are many types of candle wicks, yet the most common variant is composed of woven cotton threads, enriched with non-organic arrangements. A fibrous cotton structure of the candle wick is responsible for capillary pull of the combustible, which eventually assures a long burning time of the candle. A high-quality wick allows monitoring melting, absorption, evaporation and burning of the candle fuel. Burning depends on numerous parameters, such as type of fuel, amount of supply air, waste gas volume, as well as wick moisture. These factors determine final products of the candle combustion, which is essential to the user’s safety too. A quick and precise examination of the candle wick moisture is therefore required, particularly when this information is used for engineering purposes.

The application note includes basic information for validation of the cotton candle wicks drying method with the use of MA R, MA X2, MA X7 and MA 5Y moisture analyzers series by Radwag Wagi Elektroniczne. The application note may be the basis for elaborating own drying method with special regard to distinctive features of the product in question.
The method with the use of IR radiation
ACCURACY of determining water / dry matter content is the difference between the result of the water / dry matter content received in the moisture analyzer method and the result of the water / dry matter content received while drying the same sample through a reference method. PRECISION is a degree of compliance between independent results of the test, received in specific conditions. The measure of precision is a standard deviation from a series of several measurements.
The reference method parameters are usually specified in standards or other discipline-specific documents as the so-called guides. If such documents are unavailable, the drying temperature that does not cause the sample to change colors is used. Such an approach applies to previously dehydrated products and raw products.
Before testing, samples must be stored in sealed packaging. As for candle wicks, the sample collected for testing must be cut into pieces, ca. 4 cm long.
Laboratory dryer, glass weighing vessels with a lid, AS 220.X2 analytical balance, laboratory spoon
Place the sample with a mass of ca. 5 g in pre-dried glass weighing vessels. Specify the real mass of the sample in question with the use of the balance whose weighing accuracy is 0.1 mg (AS 220.X2). Put weighing vessels with the sample and lids into the temperature-controlled laboratory dryer. Dry sample at the temperature of 80 o C for 2 hours. After this period, remove vessels and put into the desiccator to let them cool down and then weigh. Place samples in the laboratory dryer again and keep on drying them for 30 minutes. Cool them down and weigh again. Repeat the procedure until you obtain a stable sample mass or record the sample mass growth after drying.

The water content testing with the use of the moisture analyzer (IR radiation) entails two phenomena: convection and radiation. The sample temperature rises from outer layers to the bottom of the sample. The temperature gradient in the sample structure minimizes through optimization of the thickness of the dried sample and drying temperature.
Before testing, samples must be stored in sealed packaging. As for candle wicks, the sample collected for drying must be cut into pieces, ca. 4 cm long.
MA R, MA X2, MA X7 or MA 5Y moisture analyzer, laboratory spoon, disposable aluminum weighing pans.
Set drying parameters presented below. Collect the sample with a mass of ca. 4 g and distribute its thin layer throughout the weighing pan. Lock the drying chamber manually or automatically.

Analysis time x´ (min) 5

The method in question has been verified by the Research Laboratory, yet the results do not include factors arising from diversity of tested samples, operators’ personal skills as well as measuring capability used by moisture analyzer users. For this reason Radwag shall not be held responsible for drying parameters but they can be used to elaborate own drying method.


The Vaisala viewLinc Monitoring System tracks environmental conditions wirelessly using Vaisala’s VaiNet wireless devices based on LoRa®* technology…

One of the most important requirements to reduce cooling costs is to measure conditions properly in the first place. The first things to consider are:

Carbon dioxide and other gases consisting of two or more dissimilar atoms absorb infrared (IR) radiation in a characteristic, unique manner. Such…

Another approach to preventing explosions is to install electrical equipment inside of “explosion proof” housings. These housings can withstand…
A specialist replies with the solution, the instrument and the service that fit.
Products to quote
No products yet. An enquiry can be sent anyway: a specialist answers.