Dew Point Meter DMT132
for refrigerant dryers
Technical note

Microorganisms need three factors to grow: nutrients, the right temperature, and moisture. All of these factors can exist in compressors:
Since spores from bacteria and fungi can be introduced from the environment and resist both high temperatures and dry environments, filtration and testing for contaminants in compressed air systems is extremely important.
2) What standards exist for testing compressed air?The most recent ISO standard for measuring microbial growth in compressed air is ISO 8573-7:2003, Compressed air – Part 7: Test method for viable microbiological contaminant content. ISO 8573-7 “specifies a test method for distinguishing viable, colony-forming, microbiological organisms (e.g. yeast, bacteria, endotoxins) from other solid particles which may be present in compressed air.” The standard covers nine areas, including contaminants and purity classes as well as the actual test methods for a wide range of variables including oil, gases, water, and humidity.
ISO 8573-7 requires the use of an impact air sampler capable of detecting colony-forming microbiological organisms to measure the quality of compressed air. Such machines are available from OEMs and are generally easy to integrate in production processes. However, ISO 8573-7 doesn’t specify how to avoid microbial growth in the first place. For that, it is necessary to ensure conditions are hostile to such growth.
3) How can measuring dew point help ensure end product quality?As we’ve seen, dew point is the temperature below which water vapor becomes liquid water, causing condensation. Water can cause damage to compressed air systems, but most importantly it also creates an environment where microorganisms can thrive. Dew point measurement is essential to control humidity and inhibit the growth of microorganisms, helping to ensure that food, beverage and pharmaceutical products are safe for human consumption. If the humidity in a compressed air system is found to be too high, drying is needed to bring it back down to an acceptable level.
For food and beverage and pharmaceutical applications, Vaisala offers a wide range of dew point measurement devices suitable for compressed air applications. All Vaisala sensors withstand exposure to contaminants like water spikes, ambient humidity, compressor oil, and chemical impurities.
Vaisala’s DRYCAP® technology have been trusted for decades for their accuracy and stability. Vaisala’s dew point measurement products help you to optimize the moisture levels of your production process and prevent unwanted issues such as equipment corrosion or bacteria growth. This will help to ensure high-quality compressed air and first-class end products. In addition to this, Vaisala dew point measurement products have fast wet-to-dry and dry-to-wet response times – meaning you can spot changes in the condition of compressed air immediately and avoid wasting materials and production time. DRYCAP® technology also helps to optimize compressed air quality and ensure energy savings through continuous measurement stability.
To download our latest compressed air eGuide and dew point instrument brochure, please visit our compressed air resource page.

for refrigerant dryers

for OEM applications

with ±1.5%RH accuracy for demanding volume applications

The latest addition to the Indigo family of transmitters and probes, the Indigo80 is a compact, handheld indicator and data logger. Ideal for field…

The latest addition to the Indigo family of transmitters and probes, the Indigo80 is a compact, handheld indicator and data logger. Ideal for field…

Upper air soundings provide the crucial data necessary for a complete atmospheric weather profile that leads to accurate forecasting. However…

Vaisala DRYCAP® Dew Point and Temperature Probe DMP5 is designed for in-line humidity measurement in industrial drying applications with high…

Dr. Lauri Reuter is an expert in the future of food, and the person to ask if you’ve ever wondered what we are going to eat in the future, and how…

Industrial companies are continuing to take action to minimize their carbon emissions. Many are reducing their use of fossil fuels and switching to…

In the causticizing process, passive chemicals are converted into active cooking chemicals to make white liquor. This is used in the digester as a…
A specialist replies with the solution, the instrument and the service that fit.
Products to quote
No products yet. An enquiry can be sent anyway: a specialist answers.