
Model 526 Low Temperature Calibration Source
The Isotech Model 526 is a portable low temperature calibration source designed for both laboratory and field use. It provides controlled, stable…
News
Developed particularly to complement the Model 526 Ultra-Low Dry Block Calibrator, the new probe provides a practical reference thermometer for laboratories working at very low temperatures, including cryogenic and cold-chain applications.

One of the key features of the 935-14-154 is its short 8 mm sensing element.
Temperature within a dry block is not perfectly uniform along the depth of the calibration well. A long sensing element can therefore extend across a larger axial temperature gradient and effectively average the temperature over that length.
By reducing the sensing length to just 8 mm, the 935-14-154 samples a much smaller region of the calibration volume, helping to reduce the influence of axial temperature gradients on the measurement.
The probe has a 4 mm diameter, 300 mm long stainless-steel sheath, allowing it to fit directly into the standard insert supplied with the Model 526 without requiring a specially machined insert.

With an operating range from −196 °C to 100 °C, the probe extends down to the boiling point of liquid nitrogen.
This makes it suitable for applications including low-temperature dry block calibration, cryogenic measurement, cold-chain and biobanking validation, and environmental chamber verification.
The probe uses a handmade, coil-wound Pt100 sensing element with four-wire connection, based on the established construction of Isotech’s 935-14 semi-standard thermometer range.
A spring cable relief is incorporated at the probe handle to provide additional support at the cable entry, particularly useful where the thermometer is regularly moved between dry blocks, liquid baths and dewars.
The 935-14-154 can be combined with the Model 526 Ultra-Low Dry Block Calibrator and an Isotech precision thermometer such as the milliK to provide a complete low-temperature comparison calibration system.

Isotech can also supply the probe with the required termination and calibration points, allowing it to be configured for the intended readout and application.
With a temperature range extending to liquid nitrogen temperatures, a compact sensing element and a design optimised for dry block use, the new 935-14-154 provides laboratories with a dedicated reference thermometer for demanding low-temperature calibration work.
Key specifications: −196 °C to 100 °C temperature range, 8 mm sensing length, 4 mm diameter, 300 mm sheath length, coil-wound Pt100 sensor and four-wire connection.

Isotech Semi Standard PRTs
Semi Standard Platinum Resistance Thermometers

The Isotech Model 526 is a portable low temperature calibration source designed for both laboratory and field use. It provides controlled, stable…

Need advice on which model? Dry Block Selection Guide

Need advice on which model? Dry Block Selection Guide

Need advice on which model? Dry Block Selection Guide

Need advice on which model? Dry Block Selection Guide

Need advice on which model? Dry Block Selection Guide

Between 16 and 18 November , RADWAG balances and scales could be seen at “analytica China” in Shanghai – the largest analytical, laboratory and…

As we enter the last few weeks of 2026, Isotech is reflecting on forty years of accredited calibration at its Southport laboratory. From its early…

“Polish Days in Georgia” is the most important promotional event aimed at Polish entrepreneurs in the country and designed to increase the…

RADWAG’s product range has been expanded to include AS RX Analytical Balances as well as PS RX and PS RX.M Precision Balances . This marks the next…
A specialist replies with the solution, the instrument and the service that fit.
Products to quote
No products yet. An enquiry can be sent anyway: a specialist answers.