CurrentX12-30mA

CurrentX (CurrentX12-30mA)

The CurrentX Series includes 4, 8, 12 and 16-channel low-level DC current data loggers. Includes standard calibration certificate.

Request a quoteDownload the datasheet

CurrentX (CurrentX12-30mA)

Key Features

  • Available in 3 Ranges
  • Large Memory Capacity
  • Accepts Signals from Common Voltage Sources
CurrentX (CurrentX12-30mA)

Description

The CurrentX Series includes the CurrentX4, CurrentX8, CurrentX12 and CurrentX16 low-level DC current data loggers and are available in three ranges: 30 mA, 160 mA, and 3 A.

In addition to having a large memory capacity, the CurrentX4 gives users the option to enable or disable channels to further maximize memory capacity. There’s no interface necessary, the CurrentX Series uses standard USB-A to Micro USB cable.

Using the MadgeTech Software, starting, stopping and downloading from the CurrentX Series data loggers are simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.

CurrentX (CurrentX12-30mA)

General

Memory4-channel: 1,048,064 readings; 8-channel: 524,032 readings; 12-channel: 349,354 readings; 16-channel: 262,016 readings
Reading Rate4 Hz to 1 reading every 24 hours
Channels4, 8, 12, 16
LED Indicators1 per channel and 2 status LEDs
Battery Life18 months
MaterialBlack anodized aluminum
Dimensions4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm); 8-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm); 12-channel: 2.70 in x 7.25 in x 1.68 in (65.6 mm x 184.2 mm x 42.7 mm); 16-channel: 2.70 in x 7.25 in x 2.14 in (65.6 mm x 184.2 mm x 54.4 mm)
Operating Environment-20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing

Current

Current Range-2 mA to +30 mA, ±160 mA, ±3 A
Max Voltage: Inputs & Ground3 V; (Common mode voltage must be less than 3 volts. All inputs must be within 3 volts of all other inputs.)
Current Resolution30mA: 0.0005 mA; 160mA: 0.005 mA; 3A: 0.001 A
Current Calibrate Accuracy30mA: ±0.016 mA; 160mA: ±0.16 mA; 3A: ±0.009 A
Current Input Impedance30mA: 10 Ω; 160mA: 1 Ω; 3A: 0.1 Ω