Dual-Ended Wrench (CF/M12 Wrench)
15mm and 3/4″ dual-ended wrench for use with the HiTemp140-M12 and ThermaLock
HiTemp140-M12-KR
The HiTemp140-M12 is a high temperature data logger with an M12 probe connector. Includes standard calibration certificate.
Request a quoteDownload the datasheet

The HiTemp140-M12 is a high-temperature data logger featuring an M12 probe connector. With the ability to change probes as needed, this device satisfies a multitude of application needs.
Compatible with a wide variety of M12 RTD probe styles, the HiTemp140-M12 is capable of measuring up to 500 °C (932 °F) (probe dependent). The HiTemp140-M12 records and stores up to 21,504 time-stamped readings and can be programmed for immediate start or delayed start up to 18 months in advance.
The HiTemp140-M12 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
Body of data logger cannot exceed 140 °C (284 °F), but can extend to higher temperatures when used with MadgeTech’s thermal barrier options.
| Memory | 21,504 readings |
|---|---|
| Reading Rate | 4 readings per second up to 1 reading every 24 hours |
| Baud Rate | 125,000 |
| Battery Life | 2 years typical (1 minute reading rate); Fast reading intervals and extreme temperatures will shorten the battery life substantially; User Replaceable Battery |
| Material | 316 Stainless Steel, Radel |
| Dimensions | 2.14 in x 0.97 in x 0.97 in (54.5 mm x 24.6 mm x 24.6 mm) |
| Key Ring End Cap | Key ring replaces standard bottom; Thru-hole: 0.150" |
| IP Rating | IP40 - logger alone (with no probe connected); The logger will inherit IP rating of the attached probe; (up to, and including IP68/IP69K). |
| Submersible | Yes (with probe attached) |
| Operating Environment | -40 °C to +140 °C (-40 °F to +284 °F) 0 %RH to 100 %RH non-condensing, 0.002 PSIA to 60 PSIA (Body of Logger cannot Exceed 140 °C) |
| Required Interface Package | IFC400 or IFC406 |
| Approvals | CE |
| Temperature Sensor | Various RTD Probes with M12 Connector (Sold Separately) |
|---|---|
| Temperature Resolution | 0.0001 Ω, (0.01 °C / 0.018 °F) (Probe Dependent) |
| Temperature Calibrated Accuracy | ±0.0462 Ω (18 Ω to 200 Ω); ±0.1 °C (-200 °C to +265 °C / -328 °F to +509 °F); ±0.1% of Reading (+265 °C to 500 °C / +509 °F to 932 °F); (Probe Dependent) |
| Probe Temperature Range | 18 Ω to 400 Ω, -200 °C to +500 °C (-328 °F to +932 °F) (Probe Dependent) (Body of Logger Cannot Exceed 140 °C) |
Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.
Loading the options…
A code can be pasted and the configuration builds itself.
They are quoted separately: the instrument need not be configured.

15mm and 3/4″ dual-ended wrench for use with the HiTemp140-M12 and ThermaLock


One set of replacement o-rings for the HiTemp140, RHTemp1000, PR140, PRTemp140 PR1000.






Magnetic Holder for use with the PR140, PRTemp140, HiTemp140, Temp1000, and RHTemp1000 Series Data Loggers.

Versatile mount or stand for use with the HiTemp140 series of data loggers.

Extreme Temperature Thermal Barrier for HiTemp140 Data Loggers.
Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.