HMT370EX
Intrinsically Safe Humidity and Temperature Transmitter Series HMT370EX
For use up to zone 0 and 20
Request a quoteDownload the datasheet
HMT370EX
For use up to zone 0 and 20
Request a quoteDownload the datasheet
Please note that the HMT370EX has been released with ATEX, IECEx, CML, NEPSI, KC, FM, CSA and UKEX certificates for intrinsically safe compliance.
The intrinsically safe HMT370EX is the ideal solution for use in hazardous areas up to zone 0 and 20. In addition to measuring relative humidity and temperature, the transmitter outputs also other humidity parameters: dew point temperature, wet-bulb temperature, absolute humidity, mixing ratio, water concentration, water mass fraction, water vapor pressure, and enthalpy. Special models for moisture in oil and jet fuel measurements are available.
Typical applications include fuel storage tanks, manufacturing of chemicals, pharmaceuticals and food, paint booths, and any other industry or process where intrinsically safe humidity or moisture in oil measurement is required. View the current certificates for the HMT370EX:

This next-generation HMT370EX transmitter replaces the long-running HMT360 transmitter series.
The HMT370EX offers several probe options for different applications:
Models for measuring moisture in oil and jet fuel:
The HMT370EX uses the superior Vaisala HUMICAP technology.





Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.
Loading the options…
A code can be pasted and the configuration builds itself.
They are quoted separately: the instrument need not be configured.
Intrinsically safe
The entire HMT370EX transmitter can be installed directly in explosive areas. It can withstand continuous exposure to potentially explosive environments that contain flammable liquids, gases or dust. Operation in any of these environments requires no additional protective enclosures.
Detachable probes
Probes can be easily replaced and removed for calibration outside the hazardous area without removing the entire transmitter. Attaching new probes involves minimal reconfiguration, as up-to-date settings can be restored from the transmitter.
Easy to configure
Output configuration and measurement calibration and adjustment can be carried out directly on the optional local display interface. Alternatively, you can connect the transmitter to Vaisala Insight PC software and configure both the transmitter and the probe together or separately.
Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.