The LCS140 is a Wet-Bulb/Dry-Bulb system for monitoring high temperature humidity levels. Includes ISO17025 accredited calibration certificate.
Request a quoteDownload the datasheet
LCS140
The LCS140 is a Wet-Bulb/Dry-Bulb system for monitoring high temperature humidity levels. Includes ISO17025 accredited calibration certificate.
Request a quoteDownload the datasheet
Need to record humidity at high temperatures? Look no further than the LCS140 Wet-Bulb/Dry-Bulb system. Ditch the complexity of calculating with a psychrometer, the LCS140 coupled with the MadgeTech 4 Software does all the work for you!
Capable of withstanding temperatures from -40 °C to +140 °C (-40 °F to +284 °F), the dual probe LCS140 takes wet-bulb and dry-bulb readings simultaneously to determine the amount of humidity present.
The LCS140 Includes:
(1) LCS140 Dual Probe Data Logger
(1) Aluminum Reservoir Bottle (recommended to use distilled water only)
(6) Wet-Bulb Socks
(1) Hanging Fixture
The LCS140 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
*Note: Only distilled water is recommended for use in the reservoir bottle.
| Memory | 32,767 readings |
|---|---|
| Reading Rate | 1 reading every second up to 1 reading every 24 hours |
| Battery Life | 1 year typical; Fast reading intervals and extreme temperatures will shorten the battery life substantially; User Replaceable Battery |
| Material | 316 Stainless Steel / Radel |
| IP Rating | IP68 |
| Operating Environment | -40 °C to +140 °C (-40 °F to +284 °F); 0 %RH to 100 %RH, 0.002 PSIA to 100 PSIA |
| Approvals | CE |
| Temperature Sensor | Rigid RTD Probe |
|---|---|
| Temperature Range | -40 °C to +140 °C (-40 °F to +284 °F) |
| Temperature Resolution | 0.01 °C (0.02 °F) |
| Calibrated Accuracy | ±0.1 °C (±0.18 °F) |
Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.
Loading the options…
A code can be pasted and the configuration builds itself.
They are quoted separately: the instrument need not be configured.


One set of replacement o-rings for the HiTemp140, RHTemp1000, PR140, PRTemp140 PR1000.


Brushed aluminum bottle for the LSC140 data logging system available in 4 oz and 8 oz sizes.

Replacement hanging fixture and reservoir for LCS140 data logging system.

Replacement wet-bulb socks (6-pack) for the LCS140 data logging system.