The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.

Request a quoteDownload the datasheet

MA 110.5Y.NS Moisture Analyzer

Overview

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?

If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:

It Dries in 4 Ways

The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.

  • The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.
  • The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.
  • You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.
  • The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.
MA 110.5Y.NS Moisture Analyzer

What Drying Temperature Should I Set?

The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.

The device allows drying at temperatures of up to 160 °C.

How Do I Finish the Drying? In 4 Ways

The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.

  • Automatic mode
  • Manual mode
  • Time-defined mode
  • User-defined mode
    When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.
MA 110.5Y.NS Moisture Analyzer

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.

Uncompromising User Verification

For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. ELLIPSISworks with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

MA 110.5Y.NS Moisture Analyzer

Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User

The light colour will tell you about status, process results, procedures, or alerts.

Hotspot

Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.

Live Note – Note Down Your Conclusions

It’s the first time you can add a text memo to a measurement series or procedure report. These can be, for example, assumptions, reminders or questions that can be returned to at any time.

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.

  • Full data security
  • Electronic signatures
  • Validations
  • Electronic records
  • Audit trails
MA 110.5Y.NS Moisture Analyzer

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.

A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

* RFID ISO/IEC 14443 Type A, 13.56 MHz

Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

MA 110.5Y.NS Moisture Analyzer

Metrological parameters

Maximum capacity [Max]110 g
Readability [d]1 mg
Tare range-110 g
Adjustmentexternal
Maximum sample weight110 g
Heating modulemetal heater
Moisture content repeatability±0,05 % (sample ~ 2 g), ±0,01 % (sample ~ 10 g)
Moisture content readability0,001 %
Drying temperature rangeMax 160 °C

Physical parameters

Leveling systemsemi-automatic – LevelSENSING
Display10″ graphic colour touchscreen
Weighing chamberautomatic
Delivery componentsMoisture Analyzer, disposable pan x 10, cross-shaped holder, drying pan handle, weighing pan shield, fabric dust cover, power cord
Maximum sample height20 mm
Weighing pan dimensionsø90, h= 8 mm
Packaging dimensions W x D x H540×610×470 mm
Net weight7 kg
Gross weight14 kg

Construction

Protection classIP 43

Datasheet

Display mode%D, %M, %R, g
Drying method4 drying profiles (standard, fast, step, mild)
Finish mode4 modes (automatic, manual, time-defined, user-defined)
Additional functionssample traceability
Mass indication controlExternal mass standard 50g, 100g, 200g, depending on the type of moisture analyzer (additional equipment)
Drying temperature adjustmentThree-point adjustment at defined temperatures, programmable values (additional equipment: GT105k-12/Z Control Thermometer)
Drying temperature controlOne- or two-point, depending on the drying profile (additional equipment: GT105k-12/Z Control Thermometer)
Moisture content indication controlCertified MV Test Set (additional equipment)

Communication interface

Communication interface2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi ® , Hotspot

Electrical parameters

Power supply100 – 120 V AC 50/60 Hz or 200-240 V AC 50/60 Hz
Power consumption6 W
Heating module power450 W

Ambient conditions

Operating temperature+10 – +40 °C

Functions

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.

MA 110.5Y.NS Moisture Analyzer

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

Replaceable unit

Weight function to change the weight unit.

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.

Drying modes

Method for obtaining maximum drying temperature. There are 4 drying profiles: standard, mild, step, fast. The profiles differ by which ensure various dynamics of temperature increase.

MA 110.5Y.NS Moisture Analyzer

Samples drying

Drying process enables to determine moisture content of a given sample by evaporating its free water and other components. The sample's moisture content [%M] is determined by means of precise weighing carried out before and during the drying process.

Moisture content analysis

Determination of sample's moisture content.

Dry mass determination

Determination of product mass after completed technological, physical and chemical processes enforcing product moisture evaporation. RADWAG moisture analyzers are designed to test the moisture content by heating of the samples, which is done using an IR emitter, a halogen or a metal heater.

Wi-Fi ®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

MA 110.5Y.NS Moisture Analyzer

Additional modules

RES Radwag Extended SI Module

WX-016-0154 RES level: 0,1,2 (PUE HY10)

WX-016-0212 RES level: 0,1,2 (WLY, PUE71)

WX-016-0264 RES level: 0,1,2 (4Y, 5Y)

WX-016-0265 RES level: 0,1,2 (X2, X7)

WX-016-0292 RES level: 0,1,2 (PUE HX7)

WX-016-0293 RES level: 0,1,2 (PUE C32)

21 CFR Part 11 Compliance Module

WX-001-0133 CFR 21 (4Y, 5Y, CY10)

WX-001-0187 CFR 21 (X2, X7)

The module includes "Audit Trail".

Audit Trail is a kind of a log where all modifications of balance settings, changes in database records and user activity are recorded. Audit Trail, for example, keeps record of previous and new modifications in databases and informs by whom and when they were introduced. This log allows the administrator to track and find out who logged in, when, who signed a document or who used invalid password.

The Audit Trail Reader freeware allows users, upon connection with a balance, to display Audit Trail log and manage it by generating reports of various formats: pdf, xls, csv, html.

MA 110.5Y.NS Moisture Analyzer

310 ELLIPSIS – Scan or Tap to Log In

5Y Balance and Barcode Scanner – Easy Connection

5Y Functions: Animal Weighing

5Y Functions: Checkweighing

5Y Functions: DWA®

5Y Functions: Dosing

Documents

Write on WhatsApp