A unit of AKRIBIS One

MA 210.R.NS

MA 210.R.NS Moisture Analyzer

The MA.R series is enriched with various interfaces: RS232, USB type A, USB type B and Wi-Fi®. The moisture analyzer is housed in a plastic casing. Exchange of information within the system is performed by means of USB port on bi-directional basis. It is possible to import and export databases using memory sticks.

Request a quoteDownload the datasheet

MA 210.R.NS Moisture Analyzer

Overview

Moisture analyzer is a laboratory measuring instrument intended to determine relative humidity for small samples of different materials. MA.R series redefines moisture analyzers standards. This series has been equipped with brand new readable LCD display providing an extra text line for information such as supplementary messages and data, e.g. product name or tare value. The moisture analyzer, using respective pictograms, signalizes currently activated mode, computer connection and functions, both balance and service ones.

MA.R moisture analysers – bidirectional USB communication

The MA.R series is enriched with various interfaces: RS232, USB type A, USB type B and Wi-Fi®. The moisture analyzer is housed in a plastic casing. Exchange of information within the system is performed by means of USB port on bi-directional basis. It is possible to import and export databases using memory sticks.

MA 210.R.NS Moisture Analyzer

Databases

Information system of R series moisture analyzers is based on 6 databases, allowing many operators to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 6 databases:

  • Users (up to 10 users)
  • Products (up to 1000 products)
  • Weighings (up to 1000 weighings)
  • Tares (up to 10 tares)
  • Programs (up to 100 drying programs)
  • Drying process reports(up to 1000 reports)

The results

The results obtained using the moisture analyzer (the final result of the drying process):

  • % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
  • % D– the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
  • % R– the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
  • g – the sample mass after drying.
MA 210.R.NS Moisture Analyzer

Advantages of the MA.R moisture analyser:

  • Large, backlit LCD display,
  • Uncomplicated, intuitive operation,
  • Drying profiles (standard, mild, step, fast),
  • End of the drying process (automatic, timed or manual mode),
  • GLP/GMP printouts-reports,
  • Repeatable and customized applications,
  • Heating elements: IR radiator, halogen or a heating element in a metal casing.

An additional feature that enhances the functionality of moisture analysers is a special kit for testing water vapour permeability, used, for example, in the tanning industry to determine the hygienic properties of leather.

Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

Wi-Fi® is a registered trademark of Wi-Fi Alliance®.

MA 210.R.NS Moisture Analyzer

Metrological parameters

Maximum capacity [Max]210 g
Readability [d]1 mg
Tare range-210 g
Adjustmentexternal
Maximum sample weight210 g
Heating modulemetal heater
Moisture content repeatability±0,05 % (sample ~ 2 g), ±0,01 % (sample ~ 10 g)
Moisture content readability0,001 %
Drying temperature rangeMax 160 °C

Physical parameters

Leveling systemmanual
Display5,3” LCD (backlit)
Maximum sample height20 mm
Weighing pan dimensionsø90, h= 8 mm
Packaging dimensions W x D x H476×381×346 mm
Net weight6 kg
Gross weight8 kg

Construction

Protection classIP 43

Datasheet

Display mode%D, %M, %R, g
Drying method4 drying profiles (standard, fast, step, mild)
Finish mode4 modes (automatic, manual, time-defined, user-defined)
Additional functionssample traceability
Mass indication controlExternal mass standard 50g, 100g, 200g, depending on the type of moisture analyzer (additional equipment)
Drying temperature adjustmentThree-point adjustment at defined temperatures, programmable values (additional equipment: GT105k-12/Z Control Thermometer)
Drying temperature controlOne- or two-point, depending on the drying profile (additional equipment: GT105k-12/Z Control Thermometer)
Moisture content indication controlCertified MV Test Set (additional equipment)

Communication interface

Communication interfaceRS232¹, USB-A, USB-B, Wi-Fi ®

Electrical parameters

Power supply100 – 120 V AC 50/60 Hz or 200-240 V AC 50/60 Hz
Power consumption4 W
Heating module power450 W

Ambient conditions

Operating temperature+10 – +40 °C

Functions

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

Replaceable unit

Weight function to change the weight unit.

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.

Drying modes

Method for obtaining maximum drying temperature. There are 4 drying profiles: standard, mild, step, fast. The profiles differ by which ensure various dynamics of temperature increase.

Samples drying

Drying process enables to determine moisture content of a given sample by evaporating its free water and other components. The sample's moisture content [%M] is determined by means of precise weighing carried out before and during the drying process.

Moisture content analysis

Determination of sample's moisture content.

Dry mass determination

Determination of product mass after completed technological, physical and chemical processes enforcing product moisture evaporation. RADWAG moisture analyzers are designed to test the moisture content by heating of the samples, which is done using an IR emitter, a halogen or a metal heater.

Complete Solutions for Mass Measurement in Pharma Industry

Connecting RADWAG RTP-UEW80 Printer via Wi-Fi ® (Tutorial)

MA.R - Drying Process Performed by Means of Quick Menu

MA.R - Drying Process Using Drying Programs Database

MA.R Moisture Analyzer - Quick Start

Validation of Moisture Analyzers with Sodium Chloride

Documents

Write on WhatsApp