A unit of AKRIBIS One

MA 50.X7.A

MA 50.X7.A Moisture Analyzer

is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors.

Request a quoteDownload the datasheet

MA 50.X7.A Moisture Analyzer

Overview

MA X7 moisture analyzers are hi-tech measuring instruments intended for quick determination of relative moisture content,

X7 series

is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors.

  • Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing.
  • Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity.
  • Achieving high repeatability of opening and closing the drying chamber.
  • Enhancing drying process automation.
  • Enhancing safety of operation by eliminating contact with hot components of drying chamber.
  • Improving operation ergonomics.

X7 series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product.

MA 50.X7.A Moisture Analyzer

Highlights of X7 Series moisture analyzers:

  • Automatic opening and closing of the drying chamber
  • 7” capacitive colour touchpad
  • Modern interface
  • Uncomplicated, intuitive operation
  • Programmable display
  • Drying profiles (standard, mild, step, fast)
  • GLP/GMP printouts-reports
  • Repeatable and customized applications
  • Work optimization due to the use of halogen lamps

Capacity and temperature

MA.X7 maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160°C(there is an optional moisture analyzer with 250°Cmaximum temperature).

An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather.

MA 50.X7.A Moisture Analyzer

Databases

Information system of X7 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases:

  • Products (5 000 products)
  • Users (100 users)
  • Packaging (100 packaging types)
  • Customers (1 000 customers)
  • Drying programs (200 drying programs)
  • Drying process reports (10 000 drying process reports)
  • Ambient conditions (10 000 records)
  • Weighings (50 000 records).

The results

The results obtained using the moisture analyzer (the final result of the drying process):

  • % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
  • % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
  • % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
  • g– the sample mass after drying.
MA 50.X7.A Moisture Analyzer

Interfaces

USB interfaceensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management.

Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

Metrological parameters

Maximum capacity [Max]50 g
Readability [d]1 mg
Tare range-50 g
Adjustmentexternal
Maximum sample weight50 g
Heating moduleIR emitter
Moisture content repeatability±0,05 % (sample ~ 2 g), ±0,01 % (sample ~ 10 g)
Moisture content readability0,001 %
Drying temperature rangeMax 160 °C

Physical parameters

Leveling systemmanual
Display7″ graphic colour touchscreen
Weighing chamberautomatic
Maximum sample height20 mm
Weighing pan dimensionsø90, h= 8 mm
Packaging dimensions W x D x H476×381×346 mm
Net weight6 kg
Gross weight8 kg

Construction

Protection classIP 43

Datasheet

Database capacityProducts, Users, Packaging, Customers, Drying programs, Drying process reports, Ambient Conditions, Weighings
Display mode%D, %M, %R, g
Drying method4 drying profiles (standard, fast, step, mild)
Finish mode4 modes (automatic, manual, time-defined, user-defined)
Additional functionssample traceability
Mass indication controlExternal mass standard 50g, 100g, 200g, depending on the type of moisture analyzer (additional equipment)
Drying temperature adjustmentThree-point adjustment at defined temperatures, programmable values (additional equipment: GT105k-12/Z Control Thermometer)
Drying temperature controlOne- or two-point, depending on the drying profile (additional equipment: GT105k-12/Z Control Thermometer)
Moisture content indication controlCertified MV Test Set (additional equipment)

Communication interface

Communication interfaceRS232¹, USB-A, USB-B, Ethernet, Wi-Fi ®

Electrical parameters

Power supply100 – 120 V AC 50/60 Hz or 200-240 V AC 50/60 Hz
Power consumption6 W
Heating module power450 W

Ambient conditions

Operating temperature+10 – +40 °C

Functions

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

Replaceable unit

Weight function to change the weight unit.

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.

Drying modes

Method for obtaining maximum drying temperature. There are 4 drying profiles: standard, mild, step, fast. The profiles differ by which ensure various dynamics of temperature increase.

Samples drying

Drying process enables to determine moisture content of a given sample by evaporating its free water and other components. The sample's moisture content [%M] is determined by means of precise weighing carried out before and during the drying process.

Moisture content analysis

Determination of sample's moisture content.

Dry mass determination

Determination of product mass after completed technological, physical and chemical processes enforcing product moisture evaporation. RADWAG moisture analyzers are designed to test the moisture content by heating of the samples, which is done using an IR emitter, a halogen or a metal heater.

Wi-Fi ®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Additional modules

RES Radwag Extended SI Module

WX-016-0154 RES level: 0,1,2 (PUE HY10)

WX-016-0212 RES level: 0,1,2 (WLY, PUE71)

WX-016-0264 RES level: 0,1,2 (4Y, 5Y)

WX-016-0265 RES level: 0,1,2 (X2, X7)

WX-016-0292 RES level: 0,1,2 (PUE HX7)

WX-016-0293 RES level: 0,1,2 (PUE C32)

21 CFR Part 11 Compliance Module

WX-001-0133 CFR 21 (4Y, 5Y, CY10)

WX-001-0187 CFR 21 (X2, X7)

The module includes "Audit Trail".

Audit Trail is a kind of a log where all modifications of balance settings, changes in database records and user activity are recorded. Audit Trail, for example, keeps record of previous and new modifications in databases and informs by whom and when they were introduced. This log allows the administrator to track and find out who logged in, when, who signed a document or who used invalid password.

The Audit Trail Reader freeware allows users, upon connection with a balance, to display Audit Trail log and manage it by generating reports of various formats: pdf, xls, csv, html.

MA.X7 - Drying Process Performed by Drying Process Wizard

MA.X7 - Drying Process Performed by Means of Quick Menu

MA.X7 - Drying Process Using Drying Programs Database

Measurement of Samples of High Moisture Content

New X7 Balances. AS X7 Analytical Balances and PS X7 Precision Balances

Validation of Moisture Analyzers with Sodium Chloride

Documents

Write on WhatsApp