Anti-Draft Chamber 153 (WX-002-0051)
The anti-draft chamber is intended for balances featuring a weighing pan 128×128 mm. It is an optional equipment for balances operating in…
PS 210.R2
PS.R2 balancesfeature several communication interfaces: 2 x RS232, USB-A, USB-B and optional Wireless Connection.
Request a quoteDownload the datasheet
PS.R2series balances represent a new standard of precision balances. They feature a new, readable LCD display which allows
PS.R2 balancesfeature several communication interfaces: 2 x RS232, USB-A, USB-B and optional Wireless Connection.
The balance may cooperate with computer by means of USB interface supposing a supplementary software has been installed (respective driver). The said driver may be downloaded from RADWAG website – SOFTWARE link or SUPPORT section.
The information system is based on 5 databases, which allows for several users to work with several products databases, and the registered weighing results can be subject to further analysis. The data is registered in 5 databases:

There is two directions data exchange within the system thanks to a quick USB interface. New balances allow to import and export databases using USB pen drives.
The used ALIBI memory is a data secure area and allows to record up to 100 000 weighment records. It ensures security of constant data register in the long time period.
Direct access to functions and databases is possible from the level of keyboard.
Under-pan weighing
Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook.
THBR 2.0 System
Cooperation with THBR 2.0 System for ambient conditions monitoring.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

| Maximum capacity [Max] | 210 g |
|---|---|
| Minimum load | 20 mg |
| Readability [d] | 1 mg |
| Verification unit [e] | 10 mg |
| Tare range | -210 g |
| Minimum weight (USP) | 1 g |
| Minimum weight (U=1%, k=2) | 0,1 g |
| Standard repeatability [Max] | 1 mg |
| Standard repeatability [5% Max] | 0,5 mg |
| Linearity | ±2 mg |
| Stabilization time | 2 s |
| Adjustment | internal (automatic) |
| OIML Class | II |
| Leveling system | manual |
|---|---|
| Display | 5,3” LCD (backlit) |
| Delivery components | Balance, weighing pan, weighing pan shield, grounding bumper ×1, bumper ×3, power supply. |
| Weighing pan dimensions | 128×128 mm |
| Packaging dimensions W x D x H | 475×380×345 mm |
| Net weight | 3,9 kg |
| Gross weight | 5,5 kg |
| Protection class | IP 43 |
|---|
| Communication interface | 2×RS232¹, USB-A, USB-B, Wi-Fi ® (option) |
|---|
| Power supply | Adapter: 100 – 240V AC 50/60Hz 0.6A Max; 12V DC 1,2A Balance: 12 – 15V DC 0,7A max; 3 – 5,5W* |
|---|---|
| Power consumption | 4 W |
| Operating temperature | +10 – +40 °C |
|---|---|
| Relative humidity | 40% – 80% |
Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly exceeded.
Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g ± 5 g
The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of under-pan weighing. Tested load of significant size may be measured this way.

The anti-draft chamber is intended for balances featuring a weighing pan 128×128 mm. It is an optional equipment for balances operating in…

Glass-made draft shield for precision balances with 128 x 128 weighing pan. Designed to prevent the balance from the influence of unfavourable…


The case is designed for safe transportation of PS.R, PS.X7.M, WLC.X7, WLC.A1 and WLC.A2 balances. It was made of 6-millimeter-thick plywood. It has…

Cable with jack for plugging to a car lighter 12V (PUE C315).

The table has been designed to eliminate ground vibrations during the operation of laboratory equipment such as microbalances, analytical balances…

Additional LCD display in plastic housing and on a stand. The display enables presentation of the weighing result in a place distant from the balance…

The table has been designed to eliminate ground vibrations during the operation of laboratory equipment such as microbalances, analytical balances…

The antivibration table has been designed to eliminate ground vibrations during the operation of laboratory equipment such as microbalances…

Wireless Wi-Fi® communication is a key advantage of the RADWAG RTP-UEW80 printer. The device enables convenient printing of weighing results…

LS2208 barcode scanner is a manual device designed for operation in adverse industrial conditions. It integrates with RADWAG terminals, PUE H315, PUE…

Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.