A unit of AKRIBIS One

PUE H315

PUE H315 Weighing Terminal

The LCD display has accompanied us for long years. During this time it has proven its reliability. It guarantees the readability of the result from many angles and is energy efficient.

Request a quoteDownload the datasheet

PUE H315 Weighing Terminal

Overview

The terminal is intended to be a component of a vast range of industry scales – from small table-top scales, through platform, ramp, track and pallet scales, to livestock scales. It is equipped with a stainless steel housing of high ingress protection, IP 66/IP 67/IP 69. By standard the terminal features RS 232 and USB interfaces.

It has been with us for years, and will stay for a long time to come

The LCD display has accompanied us for long years. During this time it has proven its reliability. It guarantees the readability of the result from many angles and is energy efficient.

Inner power

No access to mains power? Power failure? No problem. Thanks to its internal rechargeable battery, the H315 scale works anyway (up to 7 hours). Power supply is available at an extra charge.As standard, the scale is equipped with a RS232 cable, to which you can connect most of the accessories from our range.

PUE H315 Weighing Terminal

Not just weighing

The terminal has been equipped with numerous working modes: Parts Counting, +/- Control, Percent weighing, Totalizing, Peak Hold and Animal Weighing. Additionally, it enables defining of simple printouts in accordance with GLP procedures, and features weighing and ALIBI memory with export option, real time clock, and extensive tare functions.

Work as you like

A brand new design of the housing makes the terminal a compact device, which positively influences the comfort of operation. Another useful facility is the multifunctionally, this feature allows to operate the device when placed on a table or mounted to a post. In either case, tilt regulation is available. The said tilt regulation is also a convenience offered by a wall-mounting bracket. Besides, high ingress protection rate, which is the basic characteristic of the terminal, means failure free operation under harsh industrial conditions.

PUE H315 Weighing Terminal

Communication Interfaces and Exchange of Information with External Devices

Possibility to furnish the terminal with additional interfaces, makes its adaptation to customer requirements easy. This facilitates especially communication with stack lights and external buttons controlling scale functions (zeroing, taring and printout), and integration with unsophisticated automation systems. The terminal allows for communication with external devices such as receipt printer, additional display, computer or USB flash drive.

PUE H315 Weighing Terminal

Metrological parameters

OIML ClassIII
Maximum quantity of divisions from converter838 860 ×10
Maximum quantity of verification units6000 e
Minimum volatge per verification unit0,4 µV
Maximum voltage per verification unit3,25 µV
Minimum load cell impedance50 Ω
Maximum load cell impedance1200 Ω
Load cell excitation voltage5V DC
Maximum increase of signal39 mV
Connection of load cells4 or 6 wires + shield

Physical parameters

Display4,3” LCD (backlit)
Device dimensions W x D x H208×145×80 mm
Packaging dimensions W x D x H300×250×130 mm
Net weight1,9 kg
Gross weight2,3 kg

Construction

Protection classIP 66 / 67 / 69
Keypadmicroswitch
HousingStainless steel

Communication interface

Communication interfaceRS232, USB
Optional interfacesRS232 or RS485 or 4IN/4OUT or Ethernet or analog output 4-20 mA

Electrical parameters

Power supply100 – 240 V AC 50/60 Hz
Optional power supplyinternal rechargeable battery
Operation time on batteriesmax 7h

Ambient conditions

Operating temperature-10 – +40 °C
Storage temperature-10 – +50 °C
Relative humidity10% – 80% RH no condensation

Datasheet

Number of buttons5
Multiple range1 or 2 ranges
Additional LCD displayWD-4/1 (option)

Functions

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly exceeded.

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.

Parts counting

Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Complete Solutions for Mass Measurement in Pharma Industry

PUE H315 – Robust Weighing Terminal For the Toughest Industrial Applications

Documents

Write on WhatsApp