Temp1000Ex-5.25-KR
Temp1000Ex (Temp1000Ex-5.25-KR)
The Temp1000Ex temperature data logger carries hazardous location certification (ATEX, IECEx). Includes ISO 17025 accredited calibration certificate.
Request a quoteDownload the datasheet
Temp1000Ex-5.25-KR
The Temp1000Ex temperature data logger carries hazardous location certification (ATEX, IECEx). Includes ISO 17025 accredited calibration certificate.
Request a quoteDownload the datasheet

The Temp1000Ex is a compact, temperature data logger that carries hazardous location certification (ATEX, IECEx).
This one of a kind data logger is certified intrinsically safe for the following:
The Temp1000Ex measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C (0 °C to +55 °C) and ±0.9 °F (+32 °F to +131 °F). The Temp1000Ex can store up to 32,767 time and date stamped readings, and is available with either a flush bottom or key ring end cap.
The Temp1000Ex is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
| Memory | 65,536 Readings |
|---|---|
| Reading Rate | 1 reading every second up to 1 reading every 24 hours |
| Battery Life | 2 years typical at 15 minute reading rate |
| Material | 316 Stainless Steel/Radel |
| Dimensions | 2.66 in x .97 in dia. (67.6 mm x 24.6 mm dia.) |
| Key Ring End Cap | Key ring replaces standard bottom; Thru-hole: 0.150" |
| IP Rating | IP68 |
| Operating Environment | -40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 100 %RH (case properly sealed) |
| Required Interface Package | IFC400 or IFC406 |
| Approvals | CE; ATEX Certificate #: 19ATEX0126; IECEx Certificate #: BAS 19.0109 |
| Temperature Sensor | Resistance Temperature Detector (RTD) |
|---|---|
| Temperature Range | -40 °C to +80 °C (-40 °F to +176 °F) |
| Temperature Resolution | 0.01 °C (0.018 °F) |
| Temperature Calibrated Accuracy | ±0.5 °C (0 °C to +55 °C), ±0.9 °F (32 °F to 131 °F) |
Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.
Loading the options…
A code can be pasted and the configuration builds itself.
They are quoted separately: the instrument need not be configured.


Magnetic Holder for use with the PR140, PRTemp140, HiTemp140, Temp1000, and RHTemp1000 Series Data Loggers.



Versatile mount or stand for use with the HiTemp140 series of data loggers.

Versatile stand for use with the HiTemp140, PRTemp140, PR140, Temp1000 and RHTemp1000 series of data loggers.
Instruments to quote