VoltX8-32V
VoltX (VoltX8-32V)
The VoltX Series includes 4, 8, 12, and 16-channel DC voltage data loggers. Includes standard calibration certificate.
Request a quoteDownload the datasheet
VoltX8-32V
The VoltX Series includes 4, 8, 12, and 16-channel DC voltage data loggers. Includes standard calibration certificate.
Request a quoteDownload the datasheet

The VoltX Series includes the VoltX4, VoltX8, VoltX12, and VoltX16 DC voltage data loggers and are available in three voltage ranges: 160 mV, 3.2 V, and 32 V.
The VoltX Series accepts voltage signals from sensors, transducers and many other common voltage sources. In addition to a large storage capacity, users have the option to enable or disable channels to maximize memory capacity. There’s no interface necessary, the VoltX Series uses standard USB-A to Micro USB cable.
Using the MadgeTech Software, starting, stopping and downloading from the VoltX Series data loggers are simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.

| Memory | 4-channel: 698,709 readings; 8-channel: 349,354 readings; 12-channel: 232,903 readings; 16-channel: 174,677 readings |
|---|---|
| Reading Rate | 4 Hz up to 1 reading every 24 hours |
| Channels | 4, 8, 12, 16 |
| LEDs | 1 per channel and 2 status LEDs |
| Battery Life | 18 months |
| Material | Black anodized aluminum |
| Dimensions | 4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm); 8-channel: 2.70 in x 7.25 in x 1.22 in(65.6 mm x 184.2 mm x 31.0 mm); 12-channel: 2.70 in x 7.25 in x 1.68 in(65.6 mm x 184.2 mm x 42.7 mm); 16-channel: 2.70 in x 7.25 in x 2.14 in(65.6 mm x 184.2 mm x 54.4 mm) |
| Operating Environment | -20 ºC to +60 ºC (-4 ºF to +140 ºF),0 %RH to 95 %RH non-condensing |
| Voltage Range | ±160 mV, ±3.2 V, -8 V to +32 V |
|---|---|
| Voltage Resolution | 160 mV: 0.02 mV; 3.2 V: 0.0004 mV; 32 V: 0.004 mV |
| Voltage Calibrated Accuracy | 160 mV: ±0.032 mV; 3.2 V: ±0.0032 V; 32 V: ±0.02 V |
Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.
Loading the options…
A code can be pasted and the configuration builds itself.
They are quoted separately: the instrument need not be configured.




Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.