A unit of AKRIBIS One

E1-knob-weights-Series

Häfner E1 knob weights

Reference mass standards and weights of class E1: adjustment, testing and calibration instruments within the quality assurance of balances with more than 1 000 000 steps according to DIN EN ISO 9001 ff., for the calibration of weights of class E2 according to OIML R111, and for high-precision weighing or comparisons on mass comparators.

Request a quote

Häfner E1 knob weights

Application

E1 mass standards are used, among other applications, in quality assurance, calibration laboratories and applications with high requirements for measuring accuracy, stability and traceability. They can also be used for the calibration and verification of E2 weights according to OIML R111.

  • Testing and adjustment of high-resolution balances
  • Quality assurance of balances with a very high number of scale intervals
  • High-precision weighing and comparison measurements
  • Calibration of E2 weights
  • Metrological applications in laboratories, industry and quality assurance

Marking of E1 Mass Standards

According to OIML R111-1:2004, weights of class E1 are not marked with their nominal value or with unit information. For differentiation, weights of the same nominal value that occur more than once in weight sets can be marked with dots or stars.

In addition, up to three customer-specific user markings, such as characters, letters or numbers, can be applied. This allows the weights to be clearly identified as test or measuring equipment and better integrated into internal test equipment management.

These user markings can be specified individually when ordering.

Häfner E1 knob weights

Weight sets and cases

All weight sets include gloves, two brushes and two tweezers; sets up to 50 g come without the big tweezers, the big brush and the gloves.

Häfner E1 knob weights

Versions

Single weights, special stainless steel HE2101 g … 50 kg (15 values). Packaging: Without box, Plastic box with screwed top, Clean room plastic case, Mahogany wooden box, Clean room case with removable inserts, Service case.
Sets, special stainless steel HE2101 g–50 g … 2 kg–10 kg (13 values). Packaging: Clean room plastic case, Mahogany wooden box, Clean room case with removable inserts, Service case.
Sets, special stainless steel HE210, with mg weights (flat polygonal sheets)1 mg–5 g … 1 mg–10 kg (9 values). Packaging: Clean room plastic case, Mahogany wooden box, Clean room case with removable inserts, Service case.
Sets, special stainless steel HE210, with mg weights (wire shape)1 mg–5 g … 1 mg–10 kg (9 values). Packaging: Clean room plastic case, Mahogany wooden box, Clean room case with removable inserts, Service case.

Maximum permissible errors (OIML R111)

1 g± 0,01 mg
2 g± 0,012 mg
5 g± 0,016 mg
10 g± 0,02 mg
20 g± 0,025 mg
50 g± 0,03 mg
100 g± 0,05 mg
200 g± 0,1 mg
500 g± 0,25 mg
1 kg± 0,5 mg
2 kg± 1 mg
5 kg± 2,5 mg
10 kg± 5 mg
20 kg± 10 mg
50 kg± 25 mg

Configure the instrument

Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.