Uma unidade da AKRIBIS One

Model-461

Simple Nitrogen Boiling Point Apparatus Model 461

This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar flask filled with liquid Nitrogen, an insulating layer which houses a metallic equalising block and thermometer holder. Lastly a split insulated lid reduces evaporation and permits easy addition of liquid Nitrogen.

Solicitar cotaçãoBaixar ficha técnica

Simple Nitrogen Boiling Point Apparatus Model 461

Features

  • Safe to use
  • Economical

Description

From time to time extra liquid Nitrogen must be added, approximately every 30 minutes, to keep the dewar flask full.

The dewar flask is 100mm inside diameter and 280mm deep. The standard equalizing block houses four SPRTs or industrial thermometers up to 8mm in diameter, giving ±0.002°C temperature uniformity.

Method of Operation

A standard calibrated SPRT is placed in the equalizing block together with the sensors to be calibrated. The whole is allowed equilibriate.

The level is checked and Nitrogen added as necessary and readings taken 10 minutes afterwards.

The Isotech Simple Liquid Nitrogen Apparatus is safe to use, having no glass dewar flask internally to explode.

A comprehensive handbook accompanies the apparatus which includes an article by Henry E. Sostmann on the corrections required to convert the calibration to the ITS-90 value of the Argon Triple Point.

Specifications

Model461
Temperature Range-196°C Nominal
Uncertainty±0.002°C – the temperature distribution across the block is typically 2mK. To this must be added the uncertainty issued with the calibration certificate from the National Library. Extra uncertainties also exist if dissimilar probes are compared.
PowerN/A
Dewar DimensionsInside diameter 100mm, Depth 280mm, Volume 3 litres.
Thermometer wellsFour 8mm as standard, others to special order.
How to order461 Simple Liquid N2 Apparatus

Documentos

  • Model-459

    Cryostat Model 459

    When we considered low temperature comparison calibration, we had to take into account Health and Safety considerations, both of the liquids used in…

  • Saturn-877

    Saturn Model 877

    The Saturn spherical furnace comprises a number of concentric shells. The outer shell of spun metal is for containment and support. Inside this is a…

  • SPRT-909

    Isotech Model 909 SPRT

    This economically-priced Standard Platinum Resistance Thermometer, Model 909, is the workhorse of calibration laboratories all over the world. During…

  • Model-18205

    Nitrogen Boiling Point Apparatus Model 18205

    Isotech Nitrogen Boiling Point Apparatus is designed specifically to realise and maintain the liquid/vapour equilibrium (boiling point) of nitrogen…

  • Model-875

    Fluidised Furnace Model 875

    The Isotech Model 875 Fluidised Calibration Bath is a high-precision solution for thermometer calibration across a broad temperature range. It…