798O Large Volume Stirred Liquid Bath
The Isotech 798O Stirred Liquid Bath is an evolution in precision calibration that builds upon the legacy of the Isotech 798 series. This comparison…
SPRT-909
This economically-priced Standard Platinum Resistance Thermometer, Model 909, is the workhorse of calibration laboratories all over the world. During 2007 we reviewed our range of SPRTs and now have new models in the 909 family, the 909L and 909H. The wide temperature ranges and economic pricing make this thermometer ideal for the secondary laboratory. For smaller uncertainties to suit the Primary Laboratory refer to the Model 670 SPRTs.
Solicitar cotaçãoBaixar ficha técnica

The resistance element is of pure platinum, coiled and mounted in a strain free construction. The former is of pure alumina material and all parts have been pre-aged to eliminate contamination and strain. All joints are welded to minimize resistance changes. The leads are brought to a handle assembly where they are connected to a low loss cable, 2M long and screened.
The 909Q has a quartz sheath while the 909L and 909H have metal sheaths. Whilst metal sheathed thermometers appear more robust than the quartz glass models it should be noted that ALL SPRTs are fragile devices and must be handled with care.
Three thermometer lengths are available, standard length 480mm, extra length 550mm or maximum length 600mm.
Quartz glass thermometers have the advantage that the internal components are visible and can be inspected and continue to be our recommended models. The low temperature models have excellent immersion characteristics and a significant cost saving when compared to the higher temperature models.
The Model 909 is supplied with a calibration certificate giving RTPW and Wga. Alternatively we can provide a complete UKAS calibration certificate, see table opposite. For transportation and storage the Model 909 is supplied in its own attractive carrying case.
| Model | 909 |
|---|---|
| RTPW | 25.5Ω 100Ω |
| Nominal Resistance | 25.5Ω at 0°C 100Ω |
| Recommended max. current mA | 1 0.5 |
| Nominal Sensitivity | 0.1Ω/°C 0.4Ω/ °C |
| Resistance Ratio | Wga>1.11807 as required by ITS-90 |
| Self-heating | 1mK / 25 microwatts |
| Stability | Depends upon temperature range of use. Typical annual stability, see the table on the next page. |
| Internal Leads | 4 wire-platinum |
| External Leads | Silver-plated multi-strand wires in a low-loss insulation cable terminating in gold-plated terminals. |
| How to order | Model 909 specify model, resistance and length. State with UKAS Calibration or without UKAS Calibration. At fixed points or by comparison. |

The Isotech 798O Stirred Liquid Bath is an evolution in precision calibration that builds upon the legacy of the Isotech 798 series. This comparison…

The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S standards will cover the range from 0°C to…

If you have a large number of sensors to calibrate then this economically priced stirred liquid bath is the solution.

This model is a lower cost alternative to the ITL M 18205. This model is a simple apparatus open to the atmosphere comprising a stainless steel dewar…

Isotech Nitrogen Boiling Point Apparatus is designed specifically to realise and maintain the liquid/vapour equilibrium (boiling point) of nitrogen…

Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to…

The Saturn spherical furnace comprises a number of concentric shells. The outer shell of spun metal is for containment and support. Inside this is a…
Instrumentos para cotar
Ainda não há instrumentos. É possível escrever mesmo assim: um especialista responde.