DLS100
Versatile stand for use with the HiTemp140, PRTemp140, PR140, Temp1000 and RHTemp1000 series of data loggers.
RHTemp1000Ex-KR
The RHTemp1000Ex humidity and temperature data logger carries hazardous location certification (ATEX, IECEx). Includes ISO 17025 accredited calibration certificate.
Request a quoteDownload the datasheet
The RHTemp1000Ex is a compact, humidity and temperature data logger that carries hazardous location certification (ATEX, IECEx).
This one of a kind data logger is certified intrinsically safe for the following:
This device measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C (0 °C to ±50 °C) and ±0.9 °F (32 °F to 122 °F). The RHTemp1000Ex can store up to 32,767 time and date stamped readings, and is able to be programmed to start up to 24 months in advance.
The RHTemp1000Ex is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
| Memory | 32,767 readings |
|---|---|
| Reading Rate | 1 reading every second up to 1 reading every 24 hours |
| Battery Life | 2 years typical at 15 minute reading rate |
| Material | 316 Stainless Steel/Radel |
| Dimensions | 1.67 in x 0.97 in dia. (42.3 mm x 24.6 mm dia.) |
| IP Rating | (Not Rated) Caution: Do not submerge this product to retain IS rating. |
| Operating Environment | -40 ºC to +80 ºC (-40 °F to +176 °F); 0 %RH to 100 %RH (case properly sealed) |
| Required Interface Package | IFC400 or IFC406 |
| Approvals | CE; ATEX Certificate #: 19ATEX0126; IECEx Certificate #: BAS 19.0109 |
| Temperature Sensor | Resistance Temperature Detector (RTD) |
|---|---|
| Temperature Range | -40 °C to +80 °C (-40 °F to +176 °F) |
| Temperature Resolution | 0.01 °C (0.018 °F) |
| Temperature Calibrated Accuracy | ±0.5 °C (0 °C to ±50 °C), ±0.9 °F (32 °F to 122 °F) |
| Humidity Sensor | Capacitive Polymer |
|---|---|
| Humidity Range | 0 %RH to 100 %RH (non-condensing) |
| Humidity Resolution | 0.1 %RH |
| Humidity Calibrated Accuracy | ±3 %RH maximum |
| Humidity Specified Accuracy Range | 25 %RH to 75 %RH; +20 °C to +40 °C (68 °F to 104 °F); Hysteresis Error 1 % typical, 3 % Maximum |
Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.
Loading the options…
A code can be pasted and the configuration builds itself.
They are quoted separately: the instrument need not be configured.

Versatile stand for use with the HiTemp140, PRTemp140, PR140, Temp1000 and RHTemp1000 series of data loggers.



Magnetic Holder for use with the PR140, PRTemp140, HiTemp140, Temp1000, and RHTemp1000 Series Data Loggers.

Versatile mount or stand for use with the HiTemp140 series of data loggers.

Instruments to quote
No instruments yet. An enquiry can be sent anyway: a specialist answers.