A unit of AKRIBIS One

UTRID-16R

LogTag UTRID-16 (UTRID-16R)

Multi-use PDF Logger with integral USB connect

Request a quoteDownload the datasheet

LogTag UTRID-16 (UTRID-16R)

Highlights

  • Display showing temperature & alarm status of up to six alarms.
  • Can be connected to any computer with a USB port.
  • Automatic generation of a PDF report as a permanent record of the data.
  • Creates an encrypted data file compatible with LogTag Analyzer.
  • UTRID-16 offers both a user Replaceable battery and a Fixed Battery type.
LogTag UTRID-16 (UTRID-16R)

Overview

The LogTag UTRID-16 provides the facility to create a detailed PDF report without need for extra accessories and proprietary software and features a display, allowing immediate viewing of current and past temperatures as well as alarm statistics.

The display shows recording status, last recorded temperature and alarm status of up to six user-configurable alarms and duration of any temperature excursions. When the UTRID-16 is plugged into a computer's USB port using its integrated plug, a detailed PDF report of the recorded temperature data and alarms is be automatically generated.

For a more detailed data analysis, the UTRID-16 also creates an encrypted data file compatible with LogTag Analyzer® software and data management options.

LogTag UTRID-16 (UTRID-16R)

Technical Data

Product ModelUTRID-16R (Replaceable Battery). UTRID-16 (Fixed Battery) WHO PQS E006/076 qualified
Temperature Sensor Measurement range-30 °C to +60 °C (-22 °F to +140 °F)
Recorder Operating Temperature Range-30 °C to +65 °C (-22 °F to +149 °F)
Storage Temperature Range0 °C to +40 °C (32°F to +104°F)
Rated Temperature Reading AccuracyBetter than ±0.5 °C (±0.9 °F) for -20 °C to +40 °C (-4 °F to +104 °F). Better than ±0.7 °C (±1.3 °F) for -25 °C to -20 °C (-13 °F to -4 °F) & +40 °C to +60 °C (+104 °F to +140 °F). Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution0.1 °C (0.1 °F). LogTag Analyzer currently displays to one decimal place of °C or °F
Sensor Reaction TimeTypically less than 7 minutes (T90) in moving air (1m/s) in EN12830:1999
Recording Capacity16,129 temperature readings. 112 days @ 10min logging, 168 days @ 15min logging. Statistics memory (for display on LCD): Max/Min values and alarm duration values
Sampling IntervalConfigurable from 30 seconds to 18 hours
Recording Indication“REC” symbol on LCD
AlarmsThree configurable upper and three configurable lower alarms
Download TimeTypically with full memory (16,129 readings) in less than 30 seconds from time of insertion to availability of PDF report. Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® Analyzer (if configured)
EnvironmentalIEC 60529: IP64 with USB cap fitted
Power sourceUTRID-16R - CR2032 3V LiMnO2 Battery (Replaceable). UTRID-16 - CR2450 3V LiMnO2 UN38.3 approved coin cell battery (Fixed)
Battery LifeUTRID-16R: 1 year storage life before ‘start’ (if it is hibernation mode), followed by: 1 year of normal use (based on 15 minute logging, download data monthly). UTRID-16: Typically 2 years of operation with normal use (6 minute logging, statistics reviewed on the display no more than once daily for no longer than 30 seconds each time, download data monthly) provided recorder is kept within the storage temperature range when not in use
Real Time ClockBuilt-in real time clock. Rated accuracy ±25 ppm @ 25 °C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C)
Connection InterfaceUSB 2.0, A-type plug
SoftwarePDF Reader, LogTag Analyzer 2.8 or higher
Size93 mm(H) x 54.5 mm(W) x 8.6 mm(T) including protective USB cap.
Weight39g
Case MaterialPolycarbonate
PDF ReportOne page report with trip and alarm summary. Multi-page report with list of readings, including date and time
EN12830EN 12830:2018 - Temperature recorders for the transport, storage and distribution of temperature sensitive goods - Test, performance, suitability

Configure the instrument

Choose the model, probes and accessories. Incompatible combinations are blocked as you go; the remaining rules are checked when the instrument is added to the quote.

Documents

  • Protective Enclosure

    Protective Enclosure

    The LogTag® Protective Enclosure is specifically designed for LogTag® recorder products to allow use in harsh environments.

  • WMB-01

    Wall Mount Bracket WMB-01

    For all current LogTag® models excluding indicators and UTRED30/UTREL30 loggers

Write on WhatsApp